在分布式能源系统管理中,分解去中心化-安全-隐私三难题
Qinghan Sun1, Huan Ma1, Tian Zhao1,2
1Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Engineering Mechanics, Tsinghua University, Beijing, China.
Nature communications
|May 27, 2024
概括
本研究介绍了使用区块链技术的去中心化能源管理框架. 它提高了安全性和隐私,同时降低了用户的能源成本.
科学领域:
- 能源系统工程 能源系统工程
- 计算机科学和信息技术 计算机科学和信息技术
- 经济学 经济学 经济学
背景情况:
- 分散的能源系统需要管理方案,最大限度地提高社会福利,尽管分散的所有权.
- 现有的去中心化管理方案经常面临安全或隐私方面的挑战.
- 对分布式能源资源的安全,私有和高效管理的需求正在增长.
研究的目的:
- 开发一个去中心化的框架来管理分布式能源系统,以解决安全和隐私方面的问题.
- 为了利用区块链和可并行算法的强大和可验证的能源管理.
- 提高整体社会福利,降低能源系统的运营成本.
主要方法:
- 一个去中心化的框架,将区块链技术与可并行的数学算法集成在一起.
- 系统所有者对成本函数和运营约束进行掩盖的投标.
- 由同行可验证地解决子问题,由区块链再分配促进.
- 代交换决策和影子价格以达到平衡.
主要成果:
- 该框架确保了多种能源的分散,保护隐私和安全管理.
- 在测试系统中,系统总成本被证明减少了3.0%7.5%.
- 通过代决策和影子价格交换实现平衡状态.
结论:
- 拟议的框架有效地克服了分散能源管理中的安全和隐私缺点.
- 该系统通过降低成本和促进电网竞争力,有利于能源前期消费者.
- 这种方法支持更积极,更有效的电网基础设施.
相关概念视频
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
Power System Distribution
235
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
235
Secondary Distribution
84
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
84
Zones of Protection
166
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
166
Energy Diagrams - II
4.6K
Energy diagrams are important to understand the dynamics of a system. The topology of an energy diagram helps illustrate the equilibrium points of the system.
The point in the energy diagram at which the system’s potential energy is the lowest is known as the local minima. The system tends to stay in this position indefinitely unless acted upon by a net force. The slope of the potential energy diagram at the local minima is zero, indicating that zero net force is acting on the system. The...
The point in the energy diagram at which the system’s potential energy is the lowest is known as the local minima. The system tends to stay in this position indefinitely unless acted upon by a net force. The slope of the potential energy diagram at the local minima is zero, indicating that zero net force is acting on the system. The...
4.6K
Fast Decoupled and DC Powerflow
187
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
187