对比虚拟现实呼吸练习和激励性螺旋测量练习对改善患有性双脑的儿童肺功能的影响
Rajesh S1, Vadivelan Kanniappan1, B S Santhosh Kanna2
1Physiotherapy, SRM (Sri Ramaswamy Memorial) College of Physiotherapy, SRM Institute of Science and Technology, Chengalpattu, IND.
虚拟现实呼吸训练 (VRBT) 对改善脑 (CP) 儿童的肺功能有显著的益处. 这种疗法在呼吸系统康复方面比传统的激励螺旋计 (IST) 有优势.
科学领域:
- 儿科康复儿童康复中心
- 辅助技术 辅助技术 辅助技术
- 肺功能测试试验 肺功能测试
背景情况:
- 患有脑 (CP) 的儿童患有更高的呼吸功能障碍.
- 虚拟现实呼吸疗法 (VRBT) 是一种新兴的CP康复辅助技术.
研究的目的:
- 为了比较VRBT与激励螺旋计 (IST) 在改善CP儿童的肺功能方面的有效性.
主要方法:
- 一项实验性研究涉及32名患有性双性脑脊髓炎 (GMFCS I-III级) 的儿童.
- 参与者被随机分配到VRBT组或IST组.
- 测量的主要肺功能参数包括强迫生命能力 (FVC),一秒强迫呼气体积 (FEV1) 和峰值呼气流量 (PEF).
主要成果:
- 在VRBT和IST组之间观察到FVC和FEV1的显著差异.
- 与IST相比,VRBT在FVC和FEV1中表现出更好的改善.
- 在两组之间,在峰值呼气流量 (PEF) 中没有发现显著差异.
结论:
- 在患有CP的儿童中,VRBT为增强肺功能提供了显著的好处.
- 在这种人群中,VRBT是改善呼吸系统健康的有价值的治疗选择.
更多相关视频
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
09:37Evaluation of Respiratory Muscle Activation Using Respiratory Motor Control Assessment RMCA in Individuals with Chronic Spinal Cord Injury
Published on: July 19, 2013
相关概念视频
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Respiratory Volumes and Capacities I
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
Respiratory Volumes and Capacities
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...