通过速度向量成像来评估辐射动脉不同部分之间的墙壁弹性的相关性
Ge Tong1, Yihua Gao2, Dandan Yuan1
1Department of Ultrasound, The Affiliated Hospital of Yanbian University, Yanji, Jilin.
Medical ultrasonography
|May 29, 2024
概括
速度向量成像揭示了辐射动脉壁弹性的强相关性. 纵向峰值透气应变速率显示为检测动脉壁变化具有前途.
科学领域:
- 血管超声波是指血管超声波.
- 生物医学工程 生物医学工程
- 心血管成像 - 心血管成像
背景情况:
- 评估动脉弹性对于心血管健康至关重要.
- 放射性动脉功能评估有助于理解血管疾病的进展.
- 速度向量成像为动脉壁机制提供了先进的见解.
研究的目的:
- 为了评估前后辐射动脉壁弹性之间的相关性.
- 用速度向量成像来评估辐射动脉壁运动.
- 为了确定放射性动脉弹性功能的敏感参数.
主要方法:
- 对30名健康个体进行了回顾性分析.
- 使用速度向量成像用于离线分析.
- 测量了峰值静缩应变 (Ss),峰值静缩应变 (Sd),峰值静缩应变率 (SRs) 和峰值静缩应变率 (SRd).
主要成果:
- 在长轴截面中发现了Ss,SRs和SRd之间的显著正相关性 (p<0.01).
- 在长轴截面中观察到Sd的正相关性 (p<0.05).
- 在短轴截面中,在SRs和SRd之间发现了显著的正相关性 (p<0.01).
结论:
- 速度向量成像对于评估辐射动脉弹性是有效的.
- 长轴截面的纵向SRd是评估辐射动脉弹性功能的变化的一个敏感参数.
- 这项技术有助于早期检测放射性动脉病变.
相关概念视频
Assessment of blood pressure in brachial artery(one-step method)
584
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
584
Assessment of blood pressure in brachial artery(two-step method)
693
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
693
Assessment of radial pulse
817
Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
817
Pulse
501
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
501