用统和超声波检测和量化静脉腿
Maysen E Calzon1, John Blebea2, Christopher Pittman1,3
1USF Health Morsani College of Medicine, Tampa, FL, USA.
Phlebology
|May 31, 2024
概括
edemarulerTM提供了一种可靠的定量方法来测量腿部,在慢性静脉疾病评估的临床相关性方面优于双重超声波. 它有效地在CEAP分类中区分了的严重程度.
科学领域:
- 血管医学 血管医学
- 诊断成像 诊断成像 诊断成像
- 临床测量 临床测量
背景情况:
- 下肢胀是C3慢性静脉疾病的关键指标.
- 精确检测和量化瘤对于患者管理至关重要.
研究的目的:
- 开发和评估一种新的临床和双重超声 (DUS) 方法来检测和量化腿部.
- 为了比较EDEMA RulerTM和DUS在评估的严重程度方面的有效性.
主要方法:
- 47名患有静脉疾病的患者 (94条腿) 通过Edema RulerTM和DUS用修改后的苏希罗分级表进行了评估.
- 对于这两种方法,分析了观察者间可靠性和与Edema rVCSS的相关性.
主要成果:
- 与DUS (0.474) 相比,Edema RulerTM表现出高的观察者间可靠性 (0.985) 和与Edema rVCSS (0.842) 的更强的相关性.
- 在使用Edema RulerTM的CEAP分类中,在较低 (C1-C2) 和较高 (C3-C4c) 的CEAP分类之间观察到水深度的显著差异.
- DUS仅在CEAP C2和C4a分类之间显示了显著的差异.
结论:
- edem RulerTM 提供了一种可靠,定量和临床实用的方法来评估下肢.
- 与DUS相比,Edema RulerTM显示了与临床严重性得分的优异相关性,以及与CEAP分类之间更好的差异化.
相关概念视频
Assessment of the Cardiovascular System III: Palpation
311
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
311
Assessing Blood pressure in the Leg
2.4K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
2.4K
Assessing Blood pressure using a doppler ultrasound
1.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.3K
Pre-Procedural Guidelines for Assessing Blood Pressure
558
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
558