在共聚焦和STED显微镜中的光转换诱导人工物的影响和避免
Anindita Dasgupta1,2, Agnes Koerfer1,2, Boštjan Kokot3
1Institute for Applied Optics and Biophysics, Friedrich Schiller University Jena, Jena, Germany.
Nature methods
|June 4, 2024
概括
光显微镜中的光转换改变了光体的光谱特性和寿命,导致测量工件. 使用可交换染料可以防止在混焦和STED成像中出现这些问题.
科学领域:
- 先进的光学显微镜技术的技术.
- 光分子的光物理学
背景情况:
- 光显微镜容易发生光转换,这是一种涉及光漂白和光蓝化的过程.
- 光转换在持续照明下改变光体的光谱特性,影响成像准确度.
研究的目的:
- 为了研究各种光体的光转化产品的光参数.
- 在共聚焦和刺激辐射耗尽 (STED) 显微镜下分析光转换的影响.
主要方法:
- 光谱的表征和光转换的光体物种的寿命.
- 实验条件包括标准的共聚焦和STED显微镜.
主要成果:
- 观察到光光谱和光转化产品寿命的显著变化.
- 这些光谱和寿命变化可以在定量光测量中引入人工物.
结论:
- 光转换显著影响光显微镜中的定量测量.
- 采用可更换染料是一种可行的策略,以减轻光转换造成的工件.
相关概念视频
Confocal Fluorescence Microscopy
13.2K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
13.2K
Super-resolution Fluorescence Microscopy
7.0K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.0K
Phase Contrast and Differential Interference Contrast Microscopy
7.9K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
7.9K