基于对混合动力拖拉机等效因子的全球优化进行的等效消耗最小化策略
Zhen Zhu1,2,3, Yihan Zhang1, Hongwei Zhang2
1Automotive Engineering Research Institute, Jiangsu University, Zhenjiang, 212013, Jiangsu, China.
Scientific reports
|June 5, 2024
概括
这项研究优化了使用水力机械连续变速箱 (HMCVT) 的混合动力拖拉机的控制策略. 优化的策略增强了机动辅助,通过改进电池能量的利用,减少了高达3.9%的燃料消耗.
科学领域:
- 农业工程 农业工程
- 汽车工程 汽车工程
- 控制系统 控制系统
背景情况:
- 排放标准的提高和劳动力短缺推动了对高马力电动拖拉机的需求.
- 混合动力拖拉机需要先进的变速箱,如水力机械连续变量变速箱 (HMCVT),以满足运行需求.
研究的目的:
- 设计和优化混合动力拖拉机中HMCVT的控制策略.
- 通过优化电池能源使用,提高燃油经济性和电机辅助能力.
主要方法:
- 为HMCVT开发了一个相当因素的全球优化模型.
- 利用遗传算法,根据运行里程和电池初始充电状态 (SOC) 来优化离线的等效因子 (S).
- 使用MATLAB/Simulink和硬件在循环 (HIL) 测试验证了控制策略.
主要成果:
- 优化的控制策略允许在减电 (CD) 模式下延长运行.
- 在整个操作周期中最大限度地利用电池能量.
- 实现了2.939% (Simulink) 和3.909% (HIL) 的燃油经济改善.
结论:
- 拟议的控制策略有效地增强了电动机在混合动力拖拉机中的辅助作用.
- 优化HMCVT的等效系数可以显著降低拖拉机的燃料消耗.
- 该策略经过验证,可用于农业机械的实际应用.
相关概念视频
Power Factor Correction
170
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
170
Reducing Line Loss
150
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
150
Equivalent Couples
286
In mechanical engineering, the concept of equivalent couples plays a crucial role in understanding and analyzing various mechanical systems.
Two couples are considered to be equivalent if they produce the same rotational effect on a rigid body. In other words, the two couples have the same magnitude and act in the same direction, causing the same angular displacement or acceleration in the body.
For instance, consider two couples lying in the plane of the page, with one having a pair of equal...
Two couples are considered to be equivalent if they produce the same rotational effect on a rigid body. In other words, the two couples have the same magnitude and act in the same direction, causing the same angular displacement or acceleration in the body.
For instance, consider two couples lying in the plane of the page, with one having a pair of equal...
286
Equivalent Circuits for Practical Transformers
413
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
413
Transformers with Off-Nominal Turns Ratios
149
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
149
Fast Decoupled and DC Powerflow
187
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
187