适应性RAO组合二分法技术用于精确的太阳能光伏系统参数提取
P Ashwini Kumari1, C H Hussaian Basha2, Fini Fathima3
1School of Electrical and Electronics Engineering, Reva University, Bangalore, India.
Scientific reports
|June 5, 2024
概括
适应式罗二分法 (ARDM) 为光伏 (PV) 模型参数提取提供了卓越的性能. 这种新方法实现了高精度和效率,优于光伏系统优化的其他优化技术.
科学领域:
- 可再生能源工程可再生能源工程
- 计算智能是一种计算智能.
- 优化算法 优化算法
背景情况:
- 光伏 (PV) 模型参数提取是一个复杂的非线性优化问题.
- 精确的参数估计对于提高光伏系统效率和性能至关重要.
- 现有的优化技术在解决光伏参数提取的多模型复杂性方面面临挑战.
研究的目的:
- 引入一种新的优化方法,即适应式罗二分法 (ARDM),用于PV模型参数提取.
- 与最近的优化算法相比,评估ARDM的有效性和优势.
- 通过使用制造商数据表信息,对已建立的光伏模型验证ARDM的性能.
主要方法:
- 开发和实施自适应罗二分法 (ARDM) 方法.
- 对ARDM与金枪鱼群优化器,非洲的优化器和基于教学学习的优化器进行比较分析.
- 实验验证使用RTC France和PWP 201多晶光伏模型,并提供数据表.
主要成果:
- 对于各种光伏模型,ARDM在参数提取方面表现出卓越的性能.
- 统计分析证实了ARDM在竞争优化技术方面的优势.
- 模拟结果表明ARDM的处理速度快,趋同稳定,准确度高.
结论:
- 适应式罗二分法 (ARDM) 是用于PV模型参数提取的高效和准确的技术.
- 与现有方法相比,ARDM在效率和融合方面提供了显著的改进.
- 通过精确的参数估计,ARDM为优化光伏系统性能提供了强大的解决方案.
相关概念视频
Fast Decoupled and DC Powerflow
187
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
187
The Power Flow Problem and Solution
200
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
200
Node Analysis for AC Circuits
316
Consider an angioplasty system featuring a catheter equipped with a turbine, a critical tool for removing plaque deposits from coronary arteries. This intricate medical device operates using a circuit model reminiscent of a dual-node RLC circuit powered by a current-controlled voltage source.
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
316
Power Factor Correction
170
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
170
Power in a Three-Phase Circuit
312
Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
312
Maximum Power Flow and Line Loadability
107
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
107