自主三电智能织传感器用于生命信号监测
Ashaduzzaman Khan1, Mamunur Rashid1, Günter Grabher2
1V-Trion Textile Research GmbH, Millennium Park-15, 6890 Lustenau, Austria.
ACS applied materials & interfaces
|June 7, 2024
概括
本研究介绍了一种自主 triboelectric 智能织传感器 (AUTS),用于自动供电的生命体征监测. 灵活的,可洗的传感器为持续的,非侵入性的健康诊断提供了一个有前途的解决方案.
科学领域:
- 材料科学 材料科学 材料科学
- 生物医学工程 生物医学工程
- 可穿戴技术可穿戴技术
背景情况:
- 可穿戴的智能织传感器对于非侵入性生命体征监测和个性化健康管理至关重要.
- 传统的生物传感器由于耗电而面临限制,这阻碍了可穿戴医疗设备的广泛采用.
研究的目的:
- 引入一个自主 triboelectric 智能织传感器 (AUTS) 用于自动供电的生命体征监测.
- 为了证明传感器对灵活,可穿戴和可机洗生命体征检测的能力.
主要方法:
- 使用减少的石墨烯氧化物/二氧化/聚二甲基 (RGO-M-PDMS) 和聚四乙烯 (TEFLON) 编织的银电极制造AUTS.
- 将AUTS集成到呼吸带和脉冲带中,用于并发信号监控.
- 生物信号的无线传输到智能手机进行实时分析.
主要成果:
- AUTS表现出高灵敏度 (7.8 nA/kPa),快速响应时间 (≈40 ms) 和出色的稳定性 (>15,000 个周期).
- 传感器表现出显著的伸展性 (高达40%) 和机器可洗 (>20次洗).
- 呼吸道和脉信号的同时监测取得了成功,并通过无线传输.
结论:
- 开发的AUTS提供了一种自动供电,灵活和持久的解决方案,用于监测生命体征.
- 这项技术显示了实时个性化健康管理系统的巨大潜力.
- AUTS为先进的可穿戴医疗设备铺平了道路,其功能和用户便利性得到了增强.
相关概念视频
Equipments Used To Measure Blood Pressure
961
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
961
Pulse rhythm
785
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
785
Equipments Used to Measure Body Temperature
994
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
994
Assessing Body Temperature - Temporal Artery
540
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
540