灾难受害者鉴定:稳定同位素分析和未知死者的鉴定
Lesley A Chesson1, Gregory E Berg1, Mary Megyesi1
1Defense POW/MIA Accounting Agency Laboratory, Joint Base Pearl Harbor-Hickam, Honolulu, Hawaii, USA.
Journal of forensic sciences
|June 10, 2024
概括
稳定同位素分析 (SIA) 通过分析骨和牙等组织来帮助灾难受害者识别 (DVI). 这种方法有助于确定地理来源,并将遗骸联系或排除,加速识别过程.
科学领域:
- 法医科学 法医科学 法医科学
- 地质化学 地质化学
- 人类学是人类学.
背景情况:
- 灾难受害者识别 (DVI) 由于事件的持续时间和残骸状况而复杂.
- 传统的DVI方法面临的挑战是碎片化,分散或混合的遗骸.
- 准确的识别对于社区关闭至关重要.
研究的目的:
- 探索稳定同位素分析 (SIA) 在灾难受害者识别 (DVI) 中的应用.
- 评估SIA在确定地理起源和链接/排除遗骸方面的实用性.
- 评估SIA加速DVI程序的潜力.
主要方法:
- 稳定同位素分析 (SIA) 应用于各种人体组织 (头发,指甲,骨,牙).
- 分析骨原蛋白的碳和同位素,以确定饮食和来源.
- 对牙面膜碳酸盐进行源水同位素的分析,以推断地理来源.
- 对同位素特征的人体范围的计算.
主要成果:
- SIA可以重建一个人的饮食和水源,表明可能的地理来源.
- 骨原蛋白的同位素数据可以建立人内范围进行比较.
- SIA有效地将骨元素联系在一起,或者证明遗骸没有联系在一起.
- 通过缩小可能性,SIA可以减少对DNA测试的需求.
结论:
- 稳定同位素分析是增强灾难受害者识别的宝贵工具.
- 通过提供来源数据和链接/排除证据,SIA可以显著加快遗骸的识别.
- 在DVI调查中早期实施SIA策略最大限度地提高了效率.
相关概念视频
Radioactive Decay and Radiometric Dating
33.8K
Radioactivity is a spontaneous disintegration of an unstable nuclide and is a random process, as all the nuclei in the sample do not decay simultaneously. The number of disintegrations per unit time is called the activity (A), which is directly proportional to the number of nuclei in the sample. The decay constant (λ) is an average probability of decay per nucleus in unit time.
33.8K
Isotopes and Radioisotopes
8.6K
In the early 1900s, English chemist Frederick Soddy realized that an element could have atoms with different masses that were chemically indistinguishable. These different types are called isotopes — atoms of the same element that differ in mass. Isotopes differ in mass because they have different numbers of neutrons but are chemically identical because they have the same number of protons. Soddy was awarded the Nobel Prize in Chemistry in 1921 for this discovery.
An isotope containing...
An isotope containing...
8.6K
Mass Spectrometry: Isotope Effect
2.0K
Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the difference between the molecular mass. Furthermore, the intensity of these signals is dependent on the...
2.0K
Qualitative Analysis
22.2K
For solutions containing mixtures of different cations, the identity of each cation can be determined by qualitative analysis. This technique involves a series of selective precipitations with different chemical reagents, each reaction producing a characteristic precipitate for a specific group of cations. Metal ions within a group are further separated by varying the pH, heating the mixture to redissolve a precipitate, or adding other reagents to form complex ions.
For instance, group IV...
For instance, group IV...
22.2K
Mass Spectrum: Interpretation
1.2K
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a low-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.
To...
To...
1.2K