概括
一个新的Pearson相关系数差异 (PCCD) 系统使用代变化模式分解 (IVMD) 和多重频率转移键调制 (MFSK) 有效地减少室内可见光通信 (IVLC) 的噪声. 这种方法显著改善了信号噪声比率,并降低了调制信号的比特误差率.
科学领域:
- 光学通信是指光学通信.
- 信号处理 信号处理
背景情况:
- 室内可见光通信 (IVLC) 系统面临着严重的噪音挑战.
- 现有的无效化方法,如变化模式分解 (VMD),在参数选择方面存在局限性.
研究的目的:
- 为IVLC提出一种新的排斥系统,即皮尔森相关系数差异 (PCCD),用于IVLC.
- 通过减少频率调制信号中的噪声干扰来提高信号质量.
主要方法:
- 拟议的方法结合了代变化模式分解 (IVMD) 和多重频率转换键调制 (MFSK).
- PCCD系统直接确定最佳的VMD模式,并解决VMD惩罚因子选择问题.
主要成果:
- 对2FSK信号平均提高15.5dB,对4FSK信号平均提高13dB的输出信号噪声比 (SNR).
- 2FSK信号的比特错误率 (BER) 降低了55.8%,4FSK信号的比特错误率降低了54.4%.
- 在1m IVLC实验中证明了有效的噪音抑制.
结论:
- IVMD-MFSK 消除噪音系统为IVLC的降噪提供了一个强大的解决方案.
- 该系统具有很高的适用性,可以对各种频率调制信号进行无声化.
相关概念视频
Deconvolution
154
Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
154
IR Frequency Region: Fingerprint Region
864
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
864
IR Frequency Region: X–H Stretching
969
In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of 2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in...
969
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
998
Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single...
998
Discrete-time Fourier transform
305
The Discrete-Time Fourier Transform (DTFT) is an essential mathematical tool for analyzing discrete-time signals, converting them from the time domain to the frequency domain. This transformation allows for examining the frequency components of discrete signals, providing insights into their spectral characteristics. In the DTFT, the continuous integral used in the continuous-time Fourier transform is replaced by a summation to accommodate the discrete nature of the signal.
One of the notable...
One of the notable...
305
IR Spectrum
1000
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
1000