概括
微镜光纤气传感器的新总线拓学使准分布式气泄漏检测成为可能. 该系统为基础设施的多点监控提供了稳定和可重复的解决方案.
科学领域:
- 光学传感传感器是什么?
- 气安全 气安全
- 光纤技术 光纤技术 的应用.
背景情况:
- 微镜光纤传感器提供紧的尺寸和快速的信号处理.
- 全光传感器网络对于全面监控价值链至关重要.
- 有效的泄漏检测对于工业安全和基础设施完整性至关重要.
研究的目的:
- 提出并实验性地演示用于使用微镜光纤传感器检测泄漏的总线拓.
- 为传感器网络开发一个补偿光路径和耗电方案.
- 实现能够多点检测的准分布式系统.
主要方法:
- 实现一个总线链拓,集成20个微镜气传感器.
- 引入一个具有恒定电源的补偿光学路径.
- 使用分离器阵列的功率消耗方案的理论和实验建议.
主要成果:
- 成功验证了拟议的泄漏检测系统的试验.
- 在各种度中表现出良好的重复性和稳定性.
- 实现一个半分布式光纤泄漏检测系统.
结论:
- 总线链拓策略有效地实现了准分布式探测.
- 开发的系统为基础设施中多点泄漏检测提供了可行和有前途的解决方案.
- 这种方法提高了行业内的安全和监控能力.
相关概念视频
Energy Stored In A Coaxial Cable
2.1K
A coaxial cable consists of a central copper conductor used for transmitting signals, followed by an insulator shield, a metallic braided mesh that prevents signal interference, and a plastic layer that encases the entire assembly.
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field...
In the simplest form, a coaxial cable can be represented by two long hollow concentric cylinders in which the current flows in opposite directions. The magnetic field inside and outside the coaxial cable is determined by using Ampère's law. The magnetic field...
2.1K
Cable Subjected to a Distributed Load
1.4K
The analysis of suspension bridges is a complex and critical process that involves multiple factors, including the shape and tension of the main cables. The main cables of suspension bridges are subjected to distributed loads, which result in changes in tensile forces and deformation of the cable. These loads must be carefully considered to ensure that the bridge is safe and capable of supporting the weight of different loads.
1.4K
Bus Impedance Matrix
622
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
622