基于C6T+L6T频谱和QPSK调制格式的400G传输系统的通道功率管理
Optics express
|June 11, 2024
概括
一种新方法可以保护400 Gbit/s光传输系统免受受刺激拉曼散射 (SRS) 和突然系统故障引起的性能降低的影响. 这种方法确保了稳定的通道功率,可靠的数据传输.
科学领域:
- 光学通信是指光学通信.
- 光子学 是一个光子学.
- 信号处理 信号处理
背景情况:
- 在C+L频段系统中,刺激拉曼散射 (SRS) 会转移信号功率,降低性能.
- 保持通道功率平坦性对于400 Gbit/s QPSK传输至关重要.
- 系统故障可能会破坏通道电源,影响传输可靠性.
研究的目的:
- 为 400 Gbit/s C+L 频段 QPSK 系统提出和演示一种新的系统保护方法.
- 为了解决由SRS和突然系统故障引起的性能下降.
- 为多频段光学传输中通道功率管理提供参考.
主要方法:
- 实现一个填充通道装置.
- 使用放大器的输出功率锁定.
- 针对不同系统位置的故障量身定制解决方案.
主要成果:
- 展示了 400 Gbit/s C+L 频段系统的新型保护方法.
- 在故障条件下成功管理通道功率.
- 确保系统性能,尽管SRS的影响和故障.
结论:
- 拟议的填充通道装置和输出功率锁定有效地保护400 Gbit/s系统.
- 这种方法为突发故障提供了多样化的解决方案,提高了系统的稳定性.
- 为未来的多频段光学传输通道电源管理提供了宝贵的见解.
相关概念视频
Maximum Power Transfer
251
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
251
Design Example
324
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
324
Transmission Line Design Considerations
133
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
133
Maximum Power Flow and Line Loadability
107
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
107
The Maximum Power Transfer Theorem
599
Consider a linear AC Thevenin equivalent circuit connected to a load impedance.
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
The load connected draws the current, and the circuit delivers the power to the load. The alternating current flowing through the load is determined using the rectangular form of voltages, currents, network impedance, and load impedance. The average power delivered to the load is obtained from the product of the square of current and load resistance.
599
Power Factor Correction
170
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
170