[压力测量和调整装置的设计和测试,用于断裂端]
Zhongyuan Shen1, Yizhe Fan1, Xiao Zhang1
1The First Clinical Medical College, Nanjing University of Chinese Medicine, Nanjing, 210023.
概括
一个新的设备准确地实时测量和调整轴折断压力. 这项创新有助于研究骨折愈合,通过在动物实验中提供精确,动态的控制.
科学领域:
- 生物医学工程 生物医学工程
- 整形外科的研究研究.
- 手术器械开发 - 手术器械开发
背景情况:
- 精确监测骨折部位的轴向压力对于了解骨愈合至关重要.
- 现有的方法可能缺乏实时动态调整能力.
- 外部固定模型对于骨科干预的临床前评估至关重要.
研究的目的:
- 设计和验证用于实时测量和动态调整骨折部位轴向压力的装置.
- 在动物模型中评估设备的准确性和可靠性.
- 为了确定该设备在实验性骨折愈合研究中的实用性.
主要方法:
- 设计和实施了一种新的压力测量和调节装置.
- 该设备在狗骨折外部固定模型中进行了测试.
- 测量结果与校准压力传感器进行了比较,以验证.
主要成果:
- 在设备的读数和压力传感器之间发现了强烈的线性相关性.
- 该设备的测量结果可以使用系数准确地转换为实际的断裂末端压力.
- 该设备在 beagle 骨骨折模型中表现出可靠的性能.
结论:
- 开发的设备可实现精确的实时测量和动态调节轴突压力.
- 它的操作方便和准确性使它适合用于动物实验.
- 该设备显示了促进研究轴向压缩在骨折愈合中的作用的巨大潜力.
相关概念视频
Design Example: Strain Gauge Bridge or Wheatstone Bridge
1.3K
The utilization of strain gauges as transducers for converting mechanical strain into electrical signals is a common practice in various engineering applications. These strain gauges are frequently integrated into Wheatstone bridge circuits to accurately measure parameters such as force or pressure. Within this context, each element within the circuit exhibits a resistance that undergoes subtle variations when subjected to mechanical strain. The primary objective is to convert minuscule...
1.3K
Stress-Strain Diagram
6.9K
A stress-strain diagram is a crucial tool that graphically displays a material's mechanical characteristics. This diagram is derived from a tensile test performed on a carefully prepared cylindrical specimen. The specimen has two gauge marks inscribed on its central part, and the distance between these marks is known as the gauge length. The cylindrical specimen is placed in a testing machine, which applies an increasing centric load. As this load grows, so does the gauge length. This...
6.9K
Measurements of Strain
2.8K
Strain quantifies the deformation of a material under force, typically measured as normal strain, which represents the change in length when compared with the original length. Electrical strain gauges are used for enhanced accuracy. These devices consist of a conductive wire mounted on a paper backing that adheres to the material's surface. These gauges operate on the piezoresistive effect, where the wire's electrical resistance changes in response to mechanical deformation. The strain...
2.8K
Insulation Coordination
703
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
703
Circuit Breaker and Fuse Selection
747
A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
In high-voltage systems,...
747
Bioreactor Controls-I
94
Maintaining optimal conditions within fermenters is essential for maximizing microbial productivity and ensuring process efficiency. This lesson focuses on key parameters—temperature, foam, pH, carbon dioxide, oxygen, and pressure—and their precise measurement and control strategies in fermentation systems.Temperature ControlTemperature regulation is critical due to the exothermic nature of many fermentation processes. In small laboratory fermenters, temperature is commonly...
94