使用压力生物反装置和血压计测量深曲器肌肉强度的规范值:一项观察性研究
Kajal Saini1, Gurjant Singh2, Saumya Kothiyal2
1Department of Physiotherapy, Maharishi Markandeshwar Institute of Physiotherapy and Rehabilitation, Maharishi Markandeshwar (Deemed to be University), Mullana-133207, Haryana, India.
Journal of bodywork and movement therapies
|June 14, 2024
概括
与正常和体重不足的人相比,超重的成年人表现出更强的深曲肌肉力量. 这一发现适用于所有年龄组,突出显示了体重对部强度的影响.
科学领域:
- 生物力学 生物力学
- 运动学 运动学
- 物理疗法物理治疗
背景情况:
- 深曲肌肉对于维持椎脊柱稳定性至关重要.
- 评估深部曲器的强度对于了解部健康和功能很重要.
- 对于深屈曲器强度的规范值在不同的体质指数中并没有得到很好的确立.
研究的目的:
- 为了确定深曲肌强度的规范值.
- 为了研究身体质量指数 (BMI) 和深曲器强度之间的关系.
- 为了比较正常,体重不足和超重的成年人的深曲器强度.
主要方法:
- 招募了18-25岁的健康男性和女性参与者.
- 用压力生物反装置和在中性部位置的血压计来测量深曲器的强度.
- 参与者进行了下巴动,根据持续收缩期间达到的压力水平来评估强度.
主要成果:
- 深部曲器强度在21-23岁的正常和体重不足的成年人中降低,BMI范围为16.1-22.4.
- 超重的成年人 (年龄为21-23岁,BMI为25.9-29.4) 显示出明显更大的深曲器强度.
- 超重群体与其他群体之间的强度差异在所有年龄段都是一致的.
结论:
- 与正常和体重不足的成年人相比,超重的成年人中最大的深曲器强度更大.
- 部曲强度在中立的部位置上得到最佳发展.
- 这些发现有助于理解身体组成对宫肌肉强度的影响.
相关概念视频
Assessment of blood pressure in brachial artery(two-step method)
689
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
689
Sites for measruring blood pressure
1.6K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.6K
Special considerations while measuring blood pressure
717
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
717
Assessment of blood pressure in brachial artery(one-step method)
580
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
580
Measurement of Blood Pressure
909
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
909
Equipments Used To Measure Blood Pressure
957
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
957