测量分子中的核磁屏蔽
Karol Jackowski1, Marcin Wilczek1
1Laboratory of NMR Spectroscopy, Faculty of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland.
Molecules (Basel, Switzerland)
|June 19, 2024
概括
这项研究阐明了分子中的核磁屏蔽,详细说明了电子贡献和相互作用效应. 它提出了-3气体作为使用NMR光谱仪进行精确磁屏蔽测量的通用标准.
科学领域:
- 核磁共振 (NMR) 光谱学 核磁共振 (NMR) 光谱学
- 量子化学 是一个量子化学.
- 化学物理 化学物理
背景情况:
- 核磁屏蔽对于解释NMR光谱至关重要,但它的起源和测量是复杂的.
- 屏蔽的理论描述和实际的化学转移测量之间存在差异.
- 分子间相互作用使得固有分子屏蔽的确定变得复杂.
研究的目的:
- 为了阐明核磁屏蔽在二磁分子中的基本起源.
- 在NMR实践中协调屏蔽和化学转移的描述.
- 为绝对磁屏蔽测量建立可靠和通用标准.
主要方法:
- 对影响屏蔽的电子贡献和分子内和分子间相互作用的分析.
- 利用气相研究来隔离分子屏蔽与环境影响.
- 使用ab initio屏蔽计算与NMR频率测量相结合.
主要成果:
- 确定了对核磁屏蔽的关键电子和基于相互作用的贡献.
- 通过气相研究证明了在孤立分子中确定分子屏蔽的可行性.
- 拟议的-3气体作为绝对屏蔽的初级,通用参考标准.
结论:
- 通过先进的计算和实验方法,可以准确地确定核磁屏蔽.
- -3气提供了一个强大的初级标准,锁溶剂作为二级标准.
- 标准的NMR光谱仪可以用于绝对屏蔽测量,提高可访问性.
相关概念视频
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
848
An applied magnetic field causes the electrons present in the molecule to circulate, setting up a local diamagnetic current within the molecule. The local diamagnetic current arising from circulating sigma-bonding electrons induces a magnetic field, Blocal that opposes the applied magnetic field, B0. The effective magnetic field experienced by these nuclei is given by the difference between the applied and local magnetic fields in a phenomenon called local diamagnetic shielding. Essentially,...
848
π Electron Effects on Chemical Shift: Overview
1.1K
An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0,...
1.1K
π Electron Effects on Chemical Shift: Aromatic and Antiaromatic Compounds
1.2K
In aromatic compounds, such as benzene, the circulation of (4n + 2) π-electrons sets up a diamagnetic or diatropic ring current around the perimeter of the molecule. This current induces a magnetic field that opposes the external field inside the ring and reinforces it on the outside. The protons in benzene are deshielded and exhibit high chemical shifts in the range 6.5–8.5 ppm. The shielding effect at the center of the ring is evident in complex aromatic molecules, such as...
1.2K
Chemical Shift: Internal References and Solvent Effects
629
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
629
Atomic Nuclei: Nuclear Magnetic Moment
1.1K
All atomic nuclei are positively charged. When they have a nonzero spin, they behave like rotating charges. As a consequence of their charge and spin, these nuclei generate a magnetic field (B). This, in turn, gives rise to a magnetic moment (μ), which is randomly oriented in the absence of an external magnetic field. When an external magnetic field (B0) is applied, the magnetic moment vectors can align with the field or against it in 2 + 1 orientations. A hydrogen nucleus, which is just a...
1.1K
NMR Spectroscopy: Chemical Shift Overview
1.5K
The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
For instance, the proton...
1.5K