在低功率广域网 (LPWAN) 中,以自然为灵感的方法进行节能继电器选择
Anna Strzoda1, Krzysztof Grochla1
1Institute of Theoretical and Applied Informatics, Polish Academy of Science, Bałtycka 5, 44-100 Gliwice, Poland.
Sensors (Basel, Switzerland)
|June 19, 2024
概括
本研究介绍了一种以自然为灵感的算法,以提高低功率广域网 (LPWAN) 覆盖率. 节能继电器选择方法解决了盲点,并扩大了物联网 (IoT) 设备的网络范围.
科学领域:
- 无线通信网络是无线通信网络.
- 物联网 (IoT) 的物联网 (IoT) 的物联网.
- 算法设计的设计算法
背景情况:
- 低功率广域网 (LPWAN) 面临覆盖盲点,限制了它们的有效性.
- 扩展网络范围和保持能源效率是LPWAN的关键挑战,特别是电池驱动物联网设备.
研究的目的:
- 为基于LoRa的LPWANs提出一个创新的,节能的,以自然为灵感的中继选择算法.
- 解决LPWAN部署中信号范围差和覆盖盲点的挑战.
- 提高网络能源效率,扩大无线电信号覆盖范围.
主要方法:
- 一个群体行为启发的方法被用于网络中中继本地化.
- 该算法考虑了LoRa特定的因素,如扩散因子和设备能源预算.
- 模拟实验在各种多网关网络拓中进行,涉及数千个设备.
主要成果:
- 拟议的算法有效地弥合了沟通差距,减少了覆盖盲点的影响.
- 它在防止继电器电池耗尽方面明显优于参考方法.
- 启发式方法证明了精确方法的两倍以上的速度,准确性损失微不足道 (<2%).
结论:
- 开发的算法为扩大LPWAN覆盖范围和提高能源效率提供了有效的解决方案.
- 它对于在具有挑战性的环境中为电池驱动的物联网设备实现可靠通信至关重要.
- 这种以自然为灵感的方法为大规模LPWAN中中继选择提供了可扩展和高效的方法.
更多相关视频
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
1.5K
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
1.8K
相关概念视频
Pilot and Numeric Relaying
86
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
86
Directional Relays
103
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
103
Overcurrent Relays
76
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
76
Differential Relays
126
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
126
Maximum Power Transfer
251
Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
By substituting the entire circuit with...
251
Line Protection with Impedance Relays
76
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
76