Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Pipe Flowrate Measurement01:28

Pipe Flowrate Measurement

662
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
662
Assessment of Ventilation I: Respiratory Rate01:20

Assessment of Ventilation I: Respiratory Rate

1.1K
Assessment of Ventilation
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
1.1K
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

957
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
957
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

27.1K
Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
27.1K

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

McArdle disease (Glycogen Storage Disease Type V) from an exercise physiology and biochemistry perspective: Important considerations for exercise and physical activity testing and data interpretation.

Sports medicine and health science·2026
Same author

D- and L-lactate dehydrogenase reactions increase pH to lactate production and decrease pH to pyruvate production.

Frontiers in molecular biosciences·2026
Same author

<math><mrow><mover><mi>V</mi> <mo>˙</mo></mover></mrow></math> O<sub>2</sub> linear-onset kinetics spanning steady- and non-steady-state exercise.

Frontiers in physiology·2025
Same author

The missing hydrogen ion, Part-3: Science and the human flaws that compromise it.

Sports medicine and health science·2024
Same author

The missing hydrogen ion, part-2: Where the evidence leads to.

Sports medicine and health science·2024
Same author

The missing hydrogen ion, part-1: Historical precedents vs. fundamental concepts.

Sports medicine and health science·2024

相关实验视频

Updated: Jun 23, 2025

Calorespirometry: A Powerful, Noninvasive Approach to Investigate Cellular Energy Metabolism
09:08

Calorespirometry: A Powerful, Noninvasive Approach to Investigate Cellular Energy Metabolism

Published on: May 31, 2018

7.5K

评估空气流传感器方法:间接热量计中的精度.

Praneel Titheradge1, Robert Robergs2

  • 1School of Allied Health, Exercise & Sports Sciences, Charles Sturt University, Port Macquarie, New South Wales, Australia.

Scandinavian journal of medicine & science in sports
|June 19, 2024
PubMed
概括
此摘要是机器生成的。

不同的气流传感器会影响运动期间的间接热量计准确度. 运动强度会影响测量,但传感器类型不会显著改变结果,尽管在较高的通风率下,一致性会下降.

关键词:
异质性的异质性间接测热仪间接测热仪间接测热仪响应者 响应者 响应者这是一个技术错误,一个技术错误.

更多相关视频

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
08:25

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

Published on: January 8, 2019

9.4K
Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
08:44

Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies

Published on: February 2, 2024

696

相关实验视频

Last Updated: Jun 23, 2025

Calorespirometry: A Powerful, Noninvasive Approach to Investigate Cellular Energy Metabolism
09:08

Calorespirometry: A Powerful, Noninvasive Approach to Investigate Cellular Energy Metabolism

Published on: May 31, 2018

7.5K
Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
08:25

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

Published on: January 8, 2019

9.4K
Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
08:44

Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies

Published on: February 2, 2024

696

科学领域:

  • 运动生理学 运动生理学
  • 代谢测量 代谢测量
  • 生物医学工程 生物医学工程

背景情况:

  • 间接热量计对于评估运动期间的能量消耗至关重要.
  • 精确测量肺通风对于可靠的间接热量计是必不可少的.
  • 存在各种空气流传感器,每个都可能对测量精度产生影响.

研究的目的:

  • 评估三种不同的体积气流量测量方法 (轮,气动图谱,Venturi) 对过期气体分析间接热量计 (EGAIC) 的预测准确度和精度的影响.
  • 为了确定不同运动强度如何影响这些空气流量测量方法的性能,与EGAIC结合.
  • 为了提供对不同代谢车配置的EGAIC可靠性的见解.

主要方法:

  • 六名男性和14名女性在静止周期人体运动计上进行了运动测试.
  • 肺分钟通风率 (V̇E) 与热身期间的EGAIC计算同时测量,增量坡道测试到疲劳,以及在呼吸门80%的稳定状态炼.
  • 评估了三种空气流传感器方法 - - 轮机 (fT),气动图谱 (fP) 和风 (fV) - - 对它们对 VE 测量和 EGAIC 的影响.

主要成果:

  • 运动强度显著影响了V̇E测量 (p < 0.0001).
  • 特定的空气流传感器方法 (p = 0.97) 和它与运动强度的相互作用 (p = 0.91) 并没有显著影响测量结果.
  • 空气流量方法之间的协议在产生V·E的功率输出下降到150 L/min,这表明在更高的通风速率下降了精度.

结论:

  • 虽然空气流传感器类型似乎不是在运动强度之间EGAIC错误的主要驱动因素,但在更高的通风水平下,测量的精度会下降.
  • 在更高的V̇E下,这种精度降低可能会使生物学变异性,训练反应和测试-重新测试可靠性的解释复杂化.
  • 建议仔细考虑空气流传感器性能和不同代谢车系统之间的潜在差异,以准确地解释EGAIC.