患者如何体验和使用家庭血压监测? 使用UTAUT 2进行定性分析
Peter Nymberg1,2, Ida Bandel2, Beata Borgström Bolmsjö2
1School of Health and Welfare, Halmstad University, Halmstad, Sweden.
Scandinavian journal of primary health care
|June 20, 2024
概括
家庭血压监测提高了患者的安全性和与医疗保健提供者的沟通. 这种技术支持的护理方法可用于有效管理高血压.
科学领域:
- 心脏病学 心脏病学
- 医疗卫生技术 技术 技术
- 患者体验 患者体验
背景情况:
- 高血压是一个重要的心血管风险因素,需要有效的管理.
- 家庭血压监测 (HBPM) 显示出追踪高血压治疗结果的前景.
- 技术支持的护理和患者参与可以提高治疗效率,但患者的动机需要进一步研究.
研究的目的:
- 为了调查患者在家用血压监测方面的经验.
- 应用技术接受和使用的统一理论 (UTAUT 2) 框架.
- 了解患者的动机和自我监测高血压的后果.
主要方法:
- 使用焦点小组采访进行定性研究设计.
- 采访通过基于网络的平台Zoom进行.
- 使用演性内容分析分析的数据.
主要成果:
- "这一切都是关于安全感"的一个总体主题出现了.
- 患者感到受到社会因素的影响,并发现HBPM易于执行.
- 监测质量优先于价格,HBPM被认为可用于高血压随访.
结论:
- 有动机的患者发现,在家测血压需要最小的努力.
- 乙型肺炎增强了患者的安全性,并改善了与医疗保健专业人员的沟通.
- 这种方法为高血压自我管理和护理后续提供了一种可行的方法.
相关概念视频
Errors occurring during blood pressure monitoring
691
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
691
Assessment of blood pressure in brachial artery(two-step method)
689
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
689
Assessing Blood pressure using a doppler ultrasound
1.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.3K
Special considerations while measuring blood pressure
717
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
717
Equipments Used To Measure Blood Pressure
957
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
957
Assessment of blood pressure in brachial artery(one-step method)
580
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
580