植入式心脏转换器除器的存在很少在代码状态更改期间得到解决
Namratha Seetharam Meda1, Watipa Makhumalo2, Hunter Groninger3,4
1Department of Internal Medicine, MedStar Washington Hospital Center, Washington, DC, USA.
The American journal of hospice & palliative care
|June 22, 2024
概括
在对高风险患者的终身护理过程中,很少记录有关植入式心脏转换器除器 (ICD) 偏好的讨论. 提高临床医生的教育和ICD的图表可见性至关重要.
科学领域:
- 心脏病学 心脏病学
- 医学伦理 医学伦理
- 抚慰性护理是一种缓解性护理.
背景情况:
- 植入式心脏转移器除器 (ICD) 防止心脏突然死亡,但可以在终身护理期间提供不必要的冲击.
- 关于ICD停用的讨论对于临终期的患者来说至关重要.
研究的目的:
- 在不复苏 (DNR) 代码状态对话期间,确定可植入心脏转换器除器 (ICD) 偏好讨论的频率.
- 确定与高风险患者ICD禁用讨论的文档相关的因素.
主要方法:
- 对涉及ICD,DNR状态变化和随后死亡的患者住院的回顾性图表审查.
- 数据分析包括人口统计,并发症和ICD讨论的文档,以及统计学意义测试.
主要成果:
- 在129名患者中,110名 (85.3%) 缺乏关于ICD停用的记录讨论.
- 根据患者特征,临床医生类型或息护理咨询,没有发现显著差异.
- 特别提到输管或心脏转换的讨论与ICD停用讨论有关.
结论:
- 关于ICD停活的记录讨论在临终高风险患者中很少发生.
- 需要提高ICD的图表可见性,并为临床医生提供针对性的关于终身护理讨论的针对性教育.
更多相关视频
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
24.3K
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
3.2K
相关概念视频
Pulse rhythm
783
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
783
Disturbances in Heart Rhythm
933
Arrhythmia or dysrhythmia refers to an abnormal heart rhythm caused by a defect in the heart's conduction system. It can cause the heart to beat irregularly, too quickly, or too slowly, leading to symptoms like chest pain, shortness of breath, and fainting. Factors such as stress, caffeine, alcohol, nicotine, cocaine, certain drugs, congenital defects, diseases, and electrolyte abnormalities can trigger arrhythmias.
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
933
Cardiac Action Potential
1.3K
Cardiac action potentials are essential for proper heart function, enabling the rhythmic contractions needed for adequate blood circulation. Nodal cells and Purkinje fibers, specialized for electrical conduction, generate these action potentials.
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
1.3K
Electrocardiogram
2.3K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
2.3K
Errors occurring during blood pressure monitoring
691
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
691
Equipments Used To Measure Blood Pressure
957
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
957