概括
本研究引入了一种蒸汽积累系统,以提高燃煤发电厂 (CFPP) 的负载坡道速度. 新系统增强了CFPP的灵活性,可以在没有重大控制修订的情况下整合可再生能源.
科学领域:
- 电力系统工程 电力系统工程
- 整合可再生能源的整合
- 热电厂运行 热电厂运行 热电厂运行
背景情况:
- 越来越多的可再生能源需要更大的电网灵活性.
- 燃煤发电厂 (CFPP) 需要提高运营灵活性,以支持电网稳定性.
- 目前关于CFPP灵活性的研究主要集中在峰值剃须深度上,忽视了负载坡速率.
研究的目的:
- 建议和评估一个蒸汽蓄积器储存系统,以提高CFPP的负载率.
- 解决CFPP灵活性的局限性,特别是在低负载条件下.
- 为了提高CFPPs对电源道命令的响应速度.
主要方法:
- 为拟议的蒸汽蓄电系统开发和验证稳态和动态模型.
- 蒸汽积累器与轮的绕道系统的集成.
- 模拟充电和放电周期以评估性能.
主要成果:
- 拟议的系统允许负载变化为+2.13%的Pe和-8.3%的Pe,功率效率为63.6%在40%的THA.
- 该装置的负载增长率提高了1.5% Pe/min,达到3% Pe/min.
- 在没有修改原始控制的情况下,负载下降率至少达到5% Pe/min.
结论:
- 蒸汽积累器系统提供了一种高效而简单的解决方案,用于提高CFPP负载坡速率.
- 该技术增强了CFPP的灵活性,这对于整合高挥发性可再生能源至关重要.
- 该系统易于实施和有效,特别适用于低负载运行的CFPP.
相关概念视频
Control of Power Flow
264
There are several methods to control power flow in power systems:
264
Turbine-Governor Control
203
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
203
Accelerated Curing of Concrete
124
Accelerating concrete curing is achieved by applying heat and additional moisture. This process accelerates the hydration of the cement, resulting in an earlier strength gain in the concrete. Steam curing is a method wherein the concrete products are either transported through a chamber on a conveyor belt or encased in plastic, allowing steam at atmospheric pressure to circulate freely around them. This process begins with a phase of moist curing that typically lasts between 3 to 5 hours, after...
124
Power Factor Correction
168
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
168
Load-frequency control
152
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
152
Fast Decoupled and DC Powerflow
187
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
187