动脉构成模型在从脉冲波速度预测血压方面的关键作用
Aditya Satishkumar Bantwal1, Amit Kumar Bhayadia1, Hui Meng1
1Department of Mechanical and Aerospace Engineering, University at Buffalo, Buffalo, NY, 14260, USA.
Computers in biology and medicine
|June 25, 2024
概括
从脉冲波速度 (PWV) 估计血压 (BP) 需要考虑动脉壁.
科学领域:
- 生物医学工程 生物医学工程
- 心血管生理学心血管生理学
- 计算力学 计算力学 计算力学
背景情况:
- 持续监测血压对于心血管健康管理至关重要.
- 从脉冲波速度 (PWV) 估计血压 (BP) 的现有无袖方法通常依赖于简化的动脉模型,导致显著的预测错误.
- 这些错误可能源于对细壁,带有小变形的线性弹性动脉的假设.
研究的目的:
- 在没有简化动脉模型的约束的情况下,研究血压 (BP) 和脉冲波速度 (PWV) 之间的关系.
- 了解动脉壁机制如何影响BP-PWV关系.
主要方法:
- 液体结构相互作用 (FSI) 模拟在生理流动下在放射性和常见的动脉上进行.
- 使用了两种动脉壁构成模型:线性弹性模型和Holzapfel-Gasser-Ogden (HGO) 模型,该模型考虑了非线性效应.
- HGO模型结合了原纤维机制和大动脉变形.
主要成果:
- 线性弹性模型不准确地预测了恒定的PWV,无法反映生理变化.
- HGO模型准确地捕捉了非线性动脉变形,预测了正面的BP-PWV相关性.
- 在HGO模型中,PWV在心脏周期内变化高达50%.
结论:
- BP-PWV关系高度依赖于动脉构成模型,特别是辐射动脉.
- 从PWV精确估计血压需要考虑时间变化的PWV,由非线性动脉反应驱动.
- 未来的研究应该专注于精确测量时间变化的PWV,以便可靠地预测BP.
相关概念视频
Pre-Procedural Guidelines for Assessing Blood Pressure
554
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
554
Sites for measruring blood pressure
1.6K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.6K
Pulse
498
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
498
Blood Pressure
3.0K
The movement of blood in a human body, commonly referred to as blood flow, is determined by the volume of blood that traverses a certain section of the bodily system per unit time. It is the rhythmic contraction of the heart's ventricles that primarily instigates this movement. As the ventricles contract, blood is forced into the prominent arteries, which then flow from areas of greater pressure to lower pressure areas. This movement continues into smaller arteries and arterioles and...
3.0K
Assessing Blood pressure using a doppler ultrasound
1.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.3K
Measurement of Blood Pressure
909
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
909