相关实验视频
Updated: Jul 5, 2026

09:03
Eye Tracking Young Children with Autism
Published on: March 27, 2012
45.6K
远程摄像头视频头脉冲测试儿童的临床实用性 3岁以下的儿童
Kristen L Janky1, Jessie Patterson1, Elizabeth A Kelly1
1Boys Town National Research Hospital, Omaha, Nebraska, U.S.A.
The Laryngoscope
|June 26, 2024
概括
远程摄像头视频头脉冲测试 (vHIT) 是可行的,以评估幼儿的前庭功能. 这种方法提供耳朵特定的半圆通道数据,有助于诊断婴儿和幼儿的前庭功能障碍.
科学领域:
- 儿科门评估 儿科门评估
- 耳鼻喉科 耳鼻喉科 耳鼻喉科
- 神经科学是一个神经科学.
背景情况:
- 在幼儿 (<3岁) 中,静脉管功能障碍带来了诊断挑战.
- 准确评估半圆通道功能对于早期干预至关重要.
- 传统的前体检测方法可能很难在婴儿和幼儿中进行.
研究的目的:
- 评估远程摄像头视频头部脉冲测试 (vHIT) 在3岁以下儿童中的可行性和临床实用性.
- 为了证明远程摄像头vHIT在量化特定于耳朵的半圆形通道功能的应用.
- 突出远程摄像头vHIT在诊断风险儿童群体前庭功能障碍方面的潜力.
主要方法:
- 案例报告方法涉及5名年龄在6至31个月的儿童.
- 利用远程摄像头视频头脉冲测试 (vHIT) 来评估前庭功能.
- 在每种情况下,量化耳朵特定的半圆通道功能.
主要成果:
- 远程摄像头vHIT在所有五个儿科病例中都成功实施.
- 该技术提供了关于半圆通道功能的客观,特定于耳朵的数据.
- 结果证明了远程摄像头vHIT在识别前庭功能障碍方面的临床实用性.
结论:
- 遥控摄像头vHIT是一种可行的和有价值的临床工具,用于评估3岁以下儿童的前体功能.
- 这种方法提供特定于耳朵的半圆通道洞察力,增强或验证前庭功能障碍的诊断.
- 远程摄像头vHIT可以成为儿科前庭评估的有用辅助,特别是在婴儿和幼儿中.
相关概念视频
Assessment of blood pressure in brachial artery(one-step method)
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Assessing Blood pressure using a doppler ultrasound
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...