科斯莫ArduSiPM是一个紧的,空间准备的粒子探测器,使用先进的光倍增器传感器和系统芯片技术. 这种创新设计为太空任务提供了成本和开发时间优势.
科学领域:
- 粒子物理仪器仪器仪表 粒子物理仪器仪表
- 航空航天技术 航空航天技术
- 探测器开发 探测器开发
背景情况:
- 第一个全合一的闪粒子探测器ArduSiPM是在2012年使用光倍增传感器 (SiPM) 和系统在芯片 (SoC) 技术开发的.
- 耐辐射SoC的进步以及对太空任务的系统尺寸和重量减少的需求促使开发了一种新的探测器.
研究的目的:
- 介绍Cosmo ArduSiPM,这是一款用于太空任务的第二代性能提高的粒子探测器.
- 详细介绍新探测器的架构和功能,强调其适用于CubeSat模块的适用性以及其与定制ASIC系统相比的优势.
主要方法:
- 新的探测器Cosmo ArduSiPM是基于微芯片SAMV71 300MHz,32位ARM Cortex-M7 SoC.
- 它具有类似于原始ArduSiPM的模拟前端,但使用小型化的组件,装在一个CubeSat模块中.
- 该设计包括两个独立的通道,总重量为40克.
主要成果:
- 与定制ASIC解决方案相比,Cosmo ArduSiPM架构利用商业SoC,提供显著的成本和开发时间优势.
- 紧的,双通道板的重量只有40克,并适合在一个立方卫星的形式因素.
- 详细介绍了硬件特性和系统对不同光子流的响应,初步的闪电器合测试显示了增强能力的潜力.
结论:
- 科斯莫ArduSiPM代表了太空应用粒子探测器技术的重大进步,提供了一个紧,轻量级和具有成本效益的解决方案.
- 它的架构基于随时可用的SoC,确保了适应性和持续的增长潜力.
- 该探测器对未来的改进和在科学研究和太空任务中更广泛的应用有希望.
相关概念视频
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
208
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
208
Atomic Emission Spectroscopy: Instrumentation
360
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
360
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
573
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
573
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
700
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
700
Atomic Absorption Spectroscopy: Instrumentation
610
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
610
Atomic Emission Spectroscopy: Lab
156
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
156