场强度对刺激回声和运动补偿旋回声扩散张力心血管磁共振序列的影响
Andrew D Scott1, Ke Wen2, Yaqing Luo2
1Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, Guy's and St Thomas' NHS Foundation Trust, Sydney Street, London SW3 6NP, UK; National Heart and Lung Institute, Imperial College, Dovehouse Street, London SW3 6LY, UK.
概括
扩散张力心血管磁共振 (DT-CMR) 在1.5T是可行的,为3T扫描仪提供了替代方案. 虽然3T提供了更好的信号噪声比,但1.5T DT-CMR仍然可以产生有价值的心肌微结构数据.
科学领域:
- 心血管磁共振成像 - 心血管磁共振成像
- 生物医学工程 生物医学工程
- 医学物理 医学物理
背景情况:
- 活体扩散张力心血管磁共振 (DT-CMR) 是一种用于心肌微观结构表征的新兴技术.
- 虽然3T扫描仪提供更高的信号噪声比率 (SNR),但1.5T系统可能具有更少的回声平面成像器件,并且更容易获得.
- 调查1.5T的DT-CMR可行性对于更广泛的临床应用至关重要.
研究的目的:
- 为了比较DT-CMR在1.5T和3T的可行性和图像质量.
- 评估两个常见的DT-CMR序列:刺激回声采集模式 (STEAM) 和运动补偿回转回声 (MCSE).
- 评估场强度对DT-CMR关键参数的影响,如螺旋角度 (HA) 和信号与噪声比 (SNR).
主要方法:
- 20名健康的志愿者接受了1.5T和3T的中腹腔短轴DT-CMR.
- 采集在峰值静脉缩和终止静脉缩时使用 STEAM 和 MCSE 序列在匹配的空间分辨率进行.
- 分析了DT-CMR参数,比较1.5T和3T数据,有或没有blow参考数据.
主要成果:
- 主观螺旋角 (HA) 地图质量在STEAM的3T显著更好,但不是MCSE.
- 在所有收购中,信号与噪声比 (SNR) 始终高于3T (p < 0.05).
- 虽然一些参数显示了场强度之间的差异 (例如,分数异构,自向量定向),但1.5T和3T都提供了可测量的DT-CMR数据,尽管MCSE在透气中不可靠.
结论:
- 无论是 STEAM 还是 MCSE 序列都可以在 1.5T 执行,尽管 MCSE 在腹痛中不可靠.
- STEAM收购受益于在3T时的较高SNR.
- 1.5T DT-CMR是一个可行的选择,特别是在利用MCSE进行研究时,1.5T硬件更容易获得.
相关概念视频
Magnetic Resonance Imaging
5.1K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.1K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
790
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
790
Atomic Nuclei: Nuclear Relaxation Processes
644
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis, the precessing magnetic moments are randomly oriented around the z-axis.
644
¹H NMR: Interpreting Distorted and Overlapping Signals
1.0K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.0K