基于(III) 溶剂复合物的电生成化学发光方法,用于检测尿液中的3-甲基希斯提丁
Yu Liu1, Yue Li1, Manping Qian1
1Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, People's Republic of China.
Analytical and bioanalytical chemistry
|June 27, 2024
概括
一种新的电生成化学发光 (ECL) 方法可以在尿液中灵敏,非侵入性地检测3-甲基 (3-MeHis). 这种使用复合物的测定方法对肌肉蛋白分解的临床评估有前途.
科学领域:
- 分析化学 分析化学
- 生物化学 生化学
- 临床诊断 临床诊断 临床诊断
背景情况:
- 3-甲基胺 (3-MeHis) 是肌肉蛋白分解的关键生物标志物.
- 目前的3-MeHis测定方法缺乏灵敏度,简单性或非侵入性,阻碍了临床应用.
- 需要一种快速,可靠和非侵入性的方法来量化生物样本中的3-MeHis.
研究的目的:
- 开发和验证一种敏感,简单,非侵入性的电生成化学发光 (ECL) 方法,用于尿液中的3-MeH量化.
- 为了利用一种 (III) 溶剂复合物 ([Ir ((dfppy) 2 ((DMSO) Cl],Ir-DMSO) 作为ECL检测的信号试剂.
- 评估开发的ECL方法对实际临床应用的可行性,包括区分健康个人和患有特定疾病的患者.
主要方法:
- 使用电生成化学发光 (ECL) 试验量化尿液中的3-MeHis.
- 采用一种 (III) 溶剂复合物 ([Ir ((dfppy) 2 ((DMSO) Cl],Ir-DMSO) 作为信号生成试剂.
- 研究了Ir-DMSO的光发光 (PL) 和ECL反应,并分析了Ir-DMSO和3-MeHis之间的协调识别.
主要成果:
- 由于协调识别,3-MeHis的存在,Ir-DMSO的ECL强度显著增加.
- 开发的ECL方法实现了对3-MeHis在5至25μM范围内的敏感检测,检测极限为0.4μM.
- 该方法成功地区分了健康志愿者和肥胖和病患者的尿样,证明了其实际可行性.
结论:
- 成功开发了一种新,敏感,简单和非侵入性的ECL方法,用于尿液中检测3-MeH.
- 该方法依赖于一种 (III) 复合物和3-MeHis.的伊米达组之间的特定协调识别.
- 这种有前途的ECL测定为3MeHis的常规临床分析提供了具有成本效益,快速和灵敏的方法,有助于评估肌肉蛋白质分解.
更多相关视频
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
3.8K
10:14Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
12.5K
相关概念视频
Gas Chromatography: Types of Detectors-II
359
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
359
Photoluminescence: Applications
386
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
386
Ion-Exchange Chromatography
442
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
442