Jove
Visualize
联系我们
JoVE
x logofacebook logolinkedin logoyoutube logo
关于 JoVE
概览领导团队博客JoVE 帮助中心
作者
出版流程编辑委员会范围与政策同行评审常见问题投稿
图书馆员
用户评价订阅访问资源图书馆顾问委员会常见问题
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experiments存档
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教师资源中心教师网站
使用条款与条件
隐私政策
政策

相关概念视频

Instrument Calibration01:12

Instrument Calibration

171
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
171
Glassware Calibration01:11

Glassware Calibration

224
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
224
Data Validation01:15

Data Validation

160
Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
160
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

1.3K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
1.3K
Quantitative Analysis01:12

Quantitative Analysis

279
Quantitative analysis is a technique for measuring the amount of specific constituents in a sample. When the sample's composition is unknown, qualitative analysis is performed first to identify its components, which ensures that the correct substances are measured during the quantitative phase.
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
279
Development of Analytical Methods01:21

Development of Analytical Methods

406
An analytical methodology can be divided into four sequential steps: technique, method, procedure, and protocol. A technique is a scientific principle that rationalizes a specific phenomenon through chemical measurements. Adapting a technique for analyzing a sample of interest is termed a method. The procedure outlines the directions for performing the analysis via an analytical method. The protocol is the detailed guidelines on the procedure, which should be strictly followed to obtain the...
406

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Impact of age partitioning on classification discordance in pediatric ferritin reference intervals.

Clinical chemistry and laboratory medicine·2026
Same author

An improved approach to modelling patient reclassification: HbA<sub>1c</sub> as an example.

Clinical chemistry and laboratory medicine·2026
Same author

Challenges in Using Clinical Data for AI-Enabled Diagnostic Support.

Studies in health technology and informatics·2026
Same author

Integration of Continuous Glucose Monitoring With HbA<sub>1c</sub> to Improve the Detection of Prediabetes in Asian Individuals: Model Development Study.

JMIR diabetes·2026
Same author

Improving clinical interpretation of serum alpha-fetoprotein in children: using continuous and discrete reference intervals.

Clinical chemistry and laboratory medicine·2026
Same author

Establishing the laboratory error database: rationale, methodology, and a practical example.

Clinical chemistry and laboratory medicine·2026

相关实验视频

Updated: Jun 22, 2025

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
08:56

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry

Published on: November 22, 2024

608

校准 - 在医学实验室的分析过程中被低估的一个组成部分.

Oswald Sonntag1, Tze Ping Loh2

  • 1Independent Consultant, Eichenau, Germany.

Advances in laboratory medicine
|June 28, 2024
PubMed
概括

分析测量校准缺乏明确的指导方针,影响患者结果的可靠性. 这项研究突出了这一差距,以鼓励改善实验室医学中的校准实践和沟通.

科学领域:

  • 临床化学 临床化学
  • 实验室医学 实验室医学
  • 分析测量 分析测量

背景情况:

  • 可靠的患者结果取决于精确的分析测量校准.
  • 对于质量控制估计和解释,已有确定的指导方针.
  • 在标准化校准程序中仍然存在很大的差距.

研究的目的:

  • 为了解决缺乏清晰的沟通和指导方针的分析测量校准.
  • 强调校准在实验室诊断中的关键性质.
  • 启动讨论,以改善当前的校准实践.

主要方法:

  • 审查现有的文献和制造商对校准的建议.
  • 识别普遍接受的校准协议的缺失.
  • 分析非标准化校准的影响.

主要成果:

  • 目前的校准实践主要依赖于制造商的建议.
  • 在独立的,标准化的校准准则中存在明显的缺陷.
  • 这种缺乏标准化对患者结果的可靠性构成风险.

结论:

  • 缺乏明确的校准准则是实验室医学中的一个关键问题.
关键词:
校准校准的时间这就是线性线性.患者安全 患者安全质量控制质量控制质量控制

更多相关视频

Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
11:17

Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses

Published on: August 30, 2018

12.9K
Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
09:04

Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification

Published on: August 17, 2015

17.0K

相关实验视频

Last Updated: Jun 22, 2025

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
08:56

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry

Published on: November 22, 2024

608
Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
11:17

Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses

Published on: August 30, 2018

12.9K
Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
09:04

Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification

Published on: August 17, 2015

17.0K
  • 强大的分析测量程序需要标准化和改进的通信.
  • 进一步的研究和协作努力对于开发校准最佳实践至关重要.