重水微滴表面丰富较轻的同位素杂质
Abhijit Nandy1, Supratim Mondal1, Debasish Koner2
1Department of Chemistry, Indian Institute of Science Education and Research Tirupati, Tirupati 517507, India.
Journal of the American Chemical Society
|July 3, 2024
概括
水微滴显示重水 (D2O) 的分化同位素. 较轻的水杂质优先蒸发,丰富滴水表面并影响化学反应.
科学领域:
- 物理化学
- 分析化学
- 表面科学
背景情况:
- 微小的水滴促进了独特的界面反应.
- 微滴的界面结构及其对化学反应的影响尚不清楚.
研究的目的:
- 为了研究水同位素的滴滴分化.
- 了解水界结构对化学反应的影响.
主要方法:
- 重水 (D2O) 溶液的声波喷雾.
- 质谱测试 (MS) 用于分析物脱落和蒸汽分析.
- 在二进制D2O/H218O微滴中监测达金氧化.
主要成果:
- 作为质子化而非化物种被脱离的分析物.
- 达金氧化表明H216O比H218O更受欢迎.
- 较轻的水同位素杂质 (HOD/H2O) 最好从D2O微滴中蒸发.
结论:
- 在水同位素中滴滴分化的证据.
- 较轻的水同位素的表面丰富影响了界面化学.
- 基于微滴的水同位素分离的可能性.
更多相关视频
11:43Dissolved Solute Sampling Across an Oxic-Anoxic Soil-Water Interface Using Microdialysis Profilers
Published on: March 24, 2023
1.3K
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
26.6K
相关概念视频
Washing, Drying, and Ignition of Precipitates
903
After filtration, the precipitate is washed to remove coprecipitated impurities and any remaining mother liquor. Colloidal precipitates, such as silver chloride, are washed with an electrolyte (such as dilute nitric acid) to prevent the peptization of the precipitate. In the case of slightly soluble precipitates, the wash solution contains a common ion to reduce solubility. Lead sulfate, which is slightly soluble in water, is washed with dilute sulfuric acid. Similarly, wash solutions may be...
903
Precipitation and Co-precipitation
1.7K
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
1.7K
High-Resolution Mass Spectrometry (HRMS)
1.3K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.3K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
434
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
434
Precipitation Processes
442
The experimental conditions in a gravimetric analysis should be optimized to maximize the particle size and purity of the obtained precipitate. Ideally, the concentration of the precipitating reagent should be low with effective stirring to maintain low relative supersaturation for the growth of large crystals. In homogeneous precipitation, the precipitant is slowly generated by a chemical reaction in the solution to avoid local reagent excesses. For example, urea decomposes gradually to...
442
