联邦电网改革能解决互联问题吗?
Les Armstrong1, Alexa Canaan2, Christopher Knittel3,4
1Institute for Data, Systems, and Society, Massachussetts Institute of Technology (MIT), Cambridge, MA, USA.
概括
综合规划对于应对复杂挑战至关重要. 战略协调确保了有效的资源分配和目标实现.
科学领域:
- 跨学科研究
- 战略管理
背景情况:
- 目前的方法缺乏整合性.
- 这样做会阻碍进步.
研究的目的:
- 强调协调规划的必要性.
- 支持全面的战略发展.
主要方法:
- 关于规划方法的文献审查.
- 分析复杂项目管理中的案例研究.
主要成果:
- 确定了当前规划框架中的关键缺口.
- 展示了综合战略方法的好处.
结论:
- 协调,全面的规划对于成功至关重要.
- 建议实施综合战略.
相关概念视频
Reclosers and Fuses
100
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
100
The Power Flow Problem and Solution
192
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
192
Fast Decoupled and DC Powerflow
182
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
182
Primary Distribution
102
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
102
Maximum Power Flow and Line Loadability
107
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
107
Load-frequency control
150
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
150


