碳酸缓冲器与混合表面技术柱相结合,改善了强烈尾状脂质的峰值形状
Jenny M Nilsson1, David Balgoma2, Curt Pettersson1
1Department of Medicinal Chemistry, Uppsala Biomedical Centre, Uppsala University, Box 574, 75123 Uppsala, Sweden.
Analytica chimica acta
|July 5, 2024
概括
二碳酸 (ABC) 通过减少峰值尾部和增强信号强度,显著改善了染色学中的脂质检测. 这种新方法允许在单个分析中覆盖更广泛的脂质组,从而推进高通量脂质组学.
科学领域:
- 分析化学 分析化学
- 利皮多米克 (Lipidomics) 是一种消化剂.
- 质谱测量质量谱测量
背景情况:
- 酸 (PAs) 和心脂素 (CLs) 在逆相液色谱 (RPLC) 中的检测能力较差,原因是峰值尾巴.
- 目前用于这些脂质的水友互动液态染色学 (HILIC) 方法阻碍了高通量脂质组学.
- 需要改进RPLC方法,以更广泛地覆盖脂质组.
研究的目的:
- 调查二碳酸 (ABC) 对RPLC中脂质的峰值不对称性和检测能力的影响.
- 在传统的BEH C18和HST-CSH C18列上,将ABC与氨酸盐 (AFO) 进行比较.
- 开发一种单一的染色学方法,以提高脂质组覆盖率.
主要方法:
- 研究了2.5mM的ABC缓冲区 (pH8) 与AFO对峰值形状和检测能力的影响.
- 使用了传统的BEH C18和HST-CSH C18柱.
- 在负模式下使用RPLC-ESI-Q-TOF-MS分析了酸 (PA),心脂素 (CL) 和其他脂素.
主要成果:
- 2.5mM ABC和HST-CSH C18柱的组合使PA 16:0/18:1的不对称系数从8.4降低到1.6.
- 与AFO和BEH C18柱相比,PA 16:0/18:1的[M-H]−离子的峰值高度提高了多达54倍.
- 在HST-CSH C18列中,在负模式下对脂和脂的检测能力提高了 (高达28倍).
- 成功地将该方法应用于小鼠肝脏样本,揭示了以前未被检测到的内源性脂.
结论:
- 使用2.5毫米ABC显著改善了在负模式RPLC-ESI-Q-TOF-MS中对PA和其他脂质的峰值形状和检测能力.
- 带有ABC的HST-CSH C18列在单次注射中提供了增强的脂质组覆盖.
- 这种方法适合未来的高通量脂质学应用.
更多相关视频
10:23Sample Preparation for Endopeptidomic Analysis in Human Cerebrospinal Fluid
Published on: December 4, 2017
9.0K
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
2.5K
相关概念视频
High-Performance Liquid Chromatography: Introduction
1.9K
High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
In HPLC, two phases play a critical role in the separation process:
1.9K
Gas Chromatography: Types of Columns and Stationary Phases
569
Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
569
Ion Exchange
573
Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
573
High-Performance Liquid Chromatography: Elution Process
454
In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
454