准确性和可靠性用于估计功能运动范围
Evelina Nilsson1, Helena Grip2, Catharina Österlund1
1Department of Odontology, Clinical Oral Physiology, Umeå University, Umeå 901 87, Sweden.
Gait & posture
|July 6, 2024
概括
三维动力学分析使用运动面积和体积准确地测量了下巴运动范围 (ROM). 该方法为在临床环境中评估功能提供了可靠的工具.
科学领域:
- 生物力学 生物力学
- 运动学 运动学
- 医疗技术 医疗技术 医学技术
背景情况:
- 三维 (3D) 运动分析捕获了同步的和部运动系统数据.
- 传统的功能评估依赖于线性运动范围,限制了全面的分析.
- 在三个平面上整合下巴运动,可以通过运动区域和体积进行详细描述.
研究的目的:
- 为了验证功能运动范围 (ROM) 3D动力学分析的准确性,测试-重新测试可靠性和个体内可变性.
- 评估3D动力学分析在量化部运动面积和体积方面的精度.
- 用3D动力学来评估线性下和头部运动测量的可靠性.
主要方法:
- 通过测量已知的体积,评估百分比偏差和相关性来确定准确性.
- 测试重复测试的可靠性在17名没有疼痛的参与者中进行了评估,他们进行了标准化的下巴运动.
- 类内相关系数 (ICC) 和布兰德-阿尔特曼图表评估了可靠性;变量系数 (CV) 测量了会话内可重复性.
主要成果:
- 在体积 (0.03±0.59偏差) 和面积 (1.2±0.45偏差) 测量方面实现了高精度,具有强烈的线性相关性 (R2=0.99).
- 测试-再测试可靠性从中等到优秀,在Bland-Altman图片中显示出良好的协议.
- 观察到高重复性 (CVs),尽管水平下巴运动表现出较低的可靠性和更高的可变性.
结论:
- 3D动力学分析为准确可靠的功能ROM测量提供了经过验证的方法基础.
- 这种方法为评估ROM提供了新的措施,有利于治疗疼痛和功能障碍的临床干预.
- 该方法突出了自然的生物运动变异性和复杂的-头相互作用.
相关概念视频
Accuracy and Precision
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. Highly accurate measurements...
Accuracy, limits, and approximation
Accuracy, limits, and approximations are common in many fields, especially in engineering calculations. These concepts are imperative for ensuring that a given value is as close as possible to its true value.
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Statistical Analysis: Overview
When we take repeated measurements on the same or replicated samples, we will observe inconsistencies in the magnitude. These inconsistencies are called errors. To categorize and characterize these results and their errors, the researcher can use statistical analysis to determine the quality of the measurements and/or suitability of the methods.
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
Accuracy and Precision
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. Highly accurate measurements...
Accuracy and Errors in Hypothesis Testing
Hypothesis testing is a fundamental statistical tool that begins with the assumption that the null hypothesis H0 is true. During this process, two types of errors can occur: Type I and Type II. A Type I error refers to the incorrect rejection of a true null hypothesis, while a Type II error involves the failure to reject a false null hypothesis.
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5% chance...
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5% chance...
Receiver Operating Characteristic Plot
A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...