使用隐藏指纹的折射率来量化和描述样本沉积的特征
1King's Forensics, Department of Analytical, Environmental & Forensic Sciences, Franklin-Wilkins Building, King's College London, 150 Stamford Street, London SE1 9NH, UK.
Forensic science international
|July 6, 2024
概括
研究人员开发了一种新的工具来量化潜伏指纹 (LFP) 中的汗水,用于药物查. 标准化采集方法对于使用LFPs进行准确的药物测试至关重要.
科学领域:
- 法医科学 法医科学 法医科学
- 分析化学 分析化学
- 生物化学 生物化学
背景情况:
- 隐形指纹 (LFPs) 主要用于识别,但显示药物查的潜力.
- 目前的LFP采集方法缺乏标准化,这阻碍了药物测试的准确解释.
- 关于LFPs中的汗液沉积变量存在有限的知识.
研究的目的:
- 为了改善药物查,在LFP中描述汗液沉积变量.
- 通过折射率验证Ridgeway工具,通过折射率量化LFPs中的汗水.
- 为药物分析提供一致的LFP采样建立最佳条件.
主要方法:
- 使用折射率与LFP质量相关联的Ridgeway工具的验证.
- 评估不同手指和沉积压力的汗液沉积一致性的实验.
- 研究采样技术,以区分汗和污染.
主要成果:
- 里奇威评分 (Rs) 与LFP质量 (r = 0.868,p < 0.01) 显示出显著的正相关性.
- 一致的沉积压力和表面在左和右食指之间没有显著差异.
- 多个累积LFP的收益比单个LFP高得多,表明汗水量更大.
- 肥和无毛布组织比手凝更有效地去除污染物,以获得仅含埃克林的LFPs.
结论:
- 里奇威工具使用折射率准确量化沉积时的LFPs.
- 既定条件促进一致的LFP采样,以进行可靠的药物查.
- 标准化的LFP采集方法对于准确的药物测试至关重要.
更多相关视频
08:12Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
Published on: March 13, 2013
12.8K
04:32Author Spotlight: Quantitative Characterization of Liquid Photosensitive Bioink Properties for Continuous Digital Light Processing Based Printing
Published on: April 14, 2023
881
相关概念视频
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
329
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
329
Total Internal Reflection Fluorescence Microscopy
5.7K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
5.7K
IR Frequency Region: Fingerprint Region
837
IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the...
837