从Kushui中提取和分离的安东素是通过乙醇-NH (NH) SO (SO) 水性两相系统
Yuanyuan Li1, Tongyu Li1, Hongxu An1
1Jingjiang College, Jiangsu University Zhenjiang 212013 PR China liyuanyuan@ujs.edu.cn.
RSC advances
|July 8, 2024
概括
这项研究优化了使用乙醇-硫酸盐水性双相系统 (ATPS) 来从库舒伊中提取安托西亚宁,实现了高回收和糖去除. 开发的ATPS方法有效地分离了有价值的安托氨酸.
科学领域:
- 食品科学 食品科学 食品科学
- 生物化学 生物化学
- 分离科学 分离科学
背景情况:
- 安西是有价值的天然颜料,具有显著的健康益处.
- 从昆等植物来源有效提取和净化反素对于它们的应用至关重要.
- 传统的提取方法可能会面临挑战,即同时将素与糖等其他化合物分开.
研究的目的:
- 开发和优化一种水性双相系统 (ATPS),用于同时提取安素和从Kushui中去除糖.
- 调查各种参数对ATPS效率的影响.
- 确定最大限度地回收和纯度的最佳条件.
主要方法:
- 使用乙醇-硫酸盐水性双相系统 (ATPS) 进行同时提取和糖去除.
- 研究了盐类型,盐和乙醇度,温度和pH的影响.
- 采用Box-Behnken设计响应表面方法 (RSM) 来优化提取参数.
主要成果:
- 酸提取的最佳条件被确定为22% (w/w) 硫酸,25% (w/w) 乙醇,pH 5和33.5°C.
- 在顶级阶段,达到了最大的分割系数5.64和78%的反素回收率.
- 证明了有效的糖去除,在底部阶段的最大回收率为70.09%.
- 通过HPLC分析证实了通过ATPS提取的安托西亚宁与传统提取的相似性,验证了ATPS的适用性.
结论:
- 乙醇-硫酸盐ATPS是一种适合和有效的方法,用于同时提取安东和从库舒伊中去除糖.
- 使用RSM确定了最佳的提取条件,从而导致高氨酸回收.
- 在低pH值和低温度下储存时,从库舒伊中提取的安托是最稳定的.
相关概念视频
Extraction: Advanced Methods
444
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
444
Precipitation and Co-precipitation
1.7K
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
1.7K
High-Performance Liquid Chromatography: Elution Process
454
In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
454
Sample Preparation for Analysis: Advanced Techniques
318
Accurate analysis of complex samples often requires advanced preparation techniques to achieve reliable and reproducible results. Samples containing inorganic or organic materials can be challenging to dissolve or decompose effectively. Standard sample preparation methods include acid digestion, fusion, dry ashing, and wet digestion.
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
318