患者对怀孕高血压疾病的远程患者监测计划的患者看法
Lea Runesha1, Nora Torres Yordan1, Arin Everett1
1Section of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, University of Chicago Medicine, MC 2050, 5841 S. Maryland Avenue, Chicago, IL, 60637, USA.
Archives of gynecology and obstetrics
|July 8, 2024
概括
远程患者监测 (RPM) 改善了产后高血压知识和满意度. 使用RPM的患者更有可能参加后续检查,这表明其在产科护理中的价值.
科学领域:
- 产科和妇科 产科和妇科
- 心血管健康 心血管健康
- 数字健康数字健康
背景情况:
- 妊娠高血压障碍 (HDP) 对母亲的健康构成风险.
- 远程患者监测 (RPM) 在改善血压控制方面表现有前途.
- 在产科中,患者对RPM的看法未得到充分研究.
研究的目的:
- 评估产后患者对高血压疾病的知识.
- 评估患者的感知和满意度,使用一个为期6周的RPM程序.
- 在黑人和非黑人患者之间比较RPM体验.
主要方法:
- 在RPM计划中对产后患者的调查数据进行描述性分析.
- 在产后1,3,6周进行调查.
- 基于患者报告的种族对反应的比较.
主要成果:
- 一周后患者对异常血压 (>160/110) 的高知识 (88%).
- 由于RPM在3周后增加了参加随访的可能性 (87.4%).
- 在6周的RPM计划中,患者满意度高 (85.5%).
- 没有统计学上显著的种族差异.
结论:
- 在RPM计划中的产后患者表现出对高血压有很好的了解.
- 患者报告高满意度和随访出席的可能性增加.
- 需要进一步的研究来探索非利用的障碍.
相关概念视频
Errors occurring during blood pressure monitoring
681
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
681
Pulse rhythm
782
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
782
Special considerations while measuring blood pressure
712
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
712
Pre-Procedural Guidelines for Assessing Blood Pressure
542
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
542
Assessing Blood pressure using a doppler ultrasound
1.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.3K
Assessment of blood pressure in brachial artery(one-step method)
573
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
573