蜂启用远程患者监测,用于高血压并发症的怀孕
Rebecca D Jones1, Cheng Peng1, Crystal D Jones1
1University of Arkansas for Medical Sciences, Little Rock, Arkansas.
Cardiovascular digital health journal
|July 11, 2024
概括
对于患有高血压的孕妇进行细胞远程患者监测,减少了压力,并显示了高满意度. 这项技术改善了农村人口获得医疗保健的机会,克服了互联网障碍.
科学领域:
- 产科和妇科 产科和妇科
- 数字健康数字健康
- 孕产妇健康 孕产妇健康
背景情况:
- 怀孕期间不治理的高血压是导致产妇死亡的主要原因,特别是在农村地区.
- 远程医疗解决方案面临挑战,因为服务不足的地区的互联网接入有限.
- 蜂支持的远程患者监测 (RPM) 提供了一个可行的替代方案,用于在没有可靠的互联网的情况下进行持续的健康监测.
研究的目的:
- 评估母亲和新生儿的临床结果.
- 为了评估患者接受细胞支持的RPM在怀孕期间血压管理.
- 调查整合RPM模型的可行性,由24 / 7护士呼叫中心支持.
主要方法:
- 一项混合方法研究,涉及20名患有高血压的孕妇.
- 使用了支持蜂的BodyTrace血压手,用于持续监测.
- 通过基线调查,后调查和半结构面试在8周内收集数据.
主要成果:
- 感知压力的显著降低 (P = .0004) 和对设备可用性的高满意度.
- 参与者报告的继续使用设备的高度意图.
- 观察到低的住院和急诊室访问率.
结论:
- 蜂支持的RPM可以有效地降低农村和低资源环境中的高血压孕妇获得医疗保健的障碍.
- 综合模型证明了患者的可接受性和改善健康结果的潜力.
- RPM技术赋予患者权力,并改善服务不足地区的护理服务.
相关概念视频
Pulse rhythm
782
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
782
Errors occurring during blood pressure monitoring
681
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
681
Hormonal Regulation
33.0K
The renin-aldosterone system is an endocrine system which guides the renal absorption of water and electrolytes, thus managing blood pressure and osmoregulation. Activation of the system begins in the kidneys with a small cluster of cells adjacent to the afferent and efferent blood vessels of the renal corpuscle. As the nephrons are filtering blood, juxtaglomerular cells monitor blood pressure. If they detect a decrease in pressure, they release the hormone renin into the bloodstream.
33.0K
Special considerations while measuring blood pressure
712
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
712
Equipments Used To Measure Blood Pressure
950
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
950
Pre-Procedural Guidelines for Assessing Blood Pressure
542
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
542