相关实验视频
Updated: Jun 21, 2025

13:23
A Protocol for Collecting and Constructing Soil Core Lysimeters
Published on: June 6, 2016
11.7K
使用微解液计的后果:为什么微解液计在干旱地区大大高估了露水量? 一个批判性的审查
Giora J Kidron1, Rafael Kronenfeld2, Bo Xiao3
1Institute of Earth Sciences, The Hebrew University, Givat Ram Campus, Jerusalem 91904, Israel.
The Science of the total environment
|July 11, 2024
概括
微解液计 (MLs) 在干旱土壤中高估了非降雨水 (NRW),特别是露水,高达1000%. 这项研究解释了偏差及其对理解干旱环境中露水形成的影响.
科学领域:
- 环境科学 环境科学
- 土壤科学 土壤科学
- 水文学的水文学
背景情况:
- 微解液计 (MLs) 广泛用于测量非降雨水 (NRW),特别是露水.
- 然而,MLs显示了干旱和半干旱地区贫土壤上的NRW的显著高估.
研究的目的:
- 为了调查NRW过高估计的原因,在贫的土壤上MLs.
- 使用MLs分析导致露水测量偏差的因素.
- 为了区分MLs在植被和荒地条件下的性能.
主要方法:
- 分析ML结构和尺寸对NRW测量的影响.
- 评估关于用于露水估计的重量差计算的假设.
- 在植被 (湿) 和荒 (干旱) 土壤环境中对ML性能进行比较.
主要成果:
- MLs可以高估干旱土壤上的露水形成的百分比到1000%.
- 测量偏差与ML设计和计算方法有关.
- 关于露水形成的误解 (例如,土壤质地,湿度) 源于不准确的ML数据.
结论:
- 在干旱地区测量露水时,标准微解度仪方法不可靠.
- 该研究强调了需要修订的方法来准确地测量NRW在干旱的环境.
- 了解露 formation 形成需要解决当前微解度仪技术中固有的偏差.
更多相关视频
09:55Surface Renewal: An Advanced Micrometeorological Method for Measuring and Processing Field-Scale Energy Flux Density Data
Published on: December 12, 2013
8.6K
10:30Soil Lysimeter Excavation for Coupled Hydrological, Geochemical, and Microbiological Investigations
Published on: September 11, 2016
10.7K
相关概念视频
Common Leveling Mistakes and Errors
71
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
71
Distance Corrections
27
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
27
Volatilization
377
Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
377
Electronic Distance Measuring Instruments
32
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
32