基于多光谱电染色装置的频谱重建模型
Shuo Wang1, Hang Yin2, Yang Li1
1State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China.
Advanced science (Weinheim, Baden-Wurttemberg, Germany)
|July 12, 2024
概括
研究人员开发了电色装置,以动态模仿自然叶子光谱,用于光谱伪装. 这项创新显著提高了光谱相似性,推进了适应性伪装和防伪技术.
科学领域:
- 材料科学 材料科学 材料科学
- 光学是什么?光学是什么?光学是什么?
- 化学 化学 化学
背景情况:
- 光谱成像需要准确的可见光谱重建,用于像光谱伪装这样的应用.
- 电色材料在色彩混合和结构适应性方面具有优势,可用于光谱重建.
研究的目的:
- 开发一种模拟模型和制造方法,用于能够复制自然叶子光谱的电色仪器.
- 通过使用先进的电色材料来增强光谱伪装能力.
主要方法:
- 超过20种pH值依赖的白色染料的分子工程,以实现所需的光谱波段.
- 使用合成染料制造电色设备的制造.
- 使用拟议的模拟模型优化光谱方差.
主要成果:
- 成功合成/制备了20多种白色染料用于光谱重建.
- 优化了设备与天然叶子之间的光谱变异,从98.9增加到10.3,相似性增加了近9倍.
- 证明了一种动态光谱复制的可行方法.
结论:
- 开发的电色仪表显示了精确的光谱重建的巨大潜力.
- 这种方法推进了适应性伪装,光谱显示和防伪的智能光电材料.
相关概念视频
IR Spectrometers
1.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.1K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
208
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
208
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
Reconstruction of Signal using Interpolation
191
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
191


