新增型单相逆变器用于光伏应用,设备数量减少
1Electrical and Electronics Engineering Department, College of Engineering and Computer Sciences, Jazan University, Jazan, Saudi Arabia.
PloS one
|July 12, 2024
概括
一个新的常用地板,增压型逆变器,更少的开关提供高效率. 一个400W的原型实现了97%的效率,证明了它的市场潜力.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
背景情况:
- 由于高效率和简单的控制,具有共同点的单阶段增压逆变器很受欢迎.
- 现有的设计往往涉及复杂的电路和许多开关.
研究的目的:
- 提出一个新的常用地板,增强型逆变器,其组件数量减少.
- 评估拟议的逆变器设计的性能和效率.
主要方法:
- 一个新的逆变器拓利用两个平行直流链电容器独立充/放电.
- 在各种输出功率级别中使用PLECS软件进行效率分析.
- 用400W原型进行实验验证.
主要成果:
- 与现有的增压式逆变器相比,拟的逆变器设计具有较少的开关.
- 模拟和实验结果显示高效率,高达97%.
- 为原型提供成本细分分析.
结论:
- 拟议的通用地面,提升型逆变器提供了一个有前途的,高效的和具有成本效益的解决方案.
- 减少开关数量和高效率使其在市场应用中具有竞争力.
相关概念视频
Three-Phase Circuits
399
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
399
Generation of Three-Phase Voltage
367
A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
As the rotor...
367
Three-Phase Voltages
223
A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
223
Power Factor Correction
167
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
167
Reducing Line Loss
150
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
150
Power Distribution in Three-phase and Single Phase Circuits
297
Power distribution within electrical circuits is a foundational aspect of residential and industrial energy systems. While single-phase power is common in residential settings, three-phase power is the standard for industrial environments with heavy machinery. Each system is different and has advantages, and it's crucial to understand the underlying principles of power distribution and material efficiency.
Single-Phase Power Distribution:
Single-phase circuits are typical in household...
Single-Phase Power Distribution:
Single-phase circuits are typical in household...
297