一个原子力显微镜和总内部反射光显微镜相关系统 (AFM-TIRF) 用于单个粒子的光成像和光谱
Xiumian Cao1,2, Wenquan Wang1, Yuanfei Jiang3
1College of Physics, Jilin University, Changchun 130012, People's Republic of China.
The Review of scientific instruments
|July 12, 2024
概括
这项研究介绍了一种新的原子力显微镜和全内部反射光显微镜 (AFM-TIRF) 系统. 这种综合方法使得单分子研究的纳米成像和光检测能够同时进行.
科学领域:
- 纳米技术纳米技术
- 光学显微镜的使用方法
- 频谱学是一种光谱学.
背景情况:
- 原子力显微镜 (AFM) 和全内部反射光显微镜 (TIRF) 对于纳米研究至关重要.
- TIRF显微镜提供了对表面敏感的成像能力.
- 整合多种技术增强了纳米规模的研究.
研究的目的:
- 开发和介绍一个新的综合系统,将AFM与多波长TIRF结合起来.
- 为了实现同时进行光成像和光谱采集.
- 为了证明系统的性能纳米分析.
主要方法:
- 仪器设计将AFM与多波长TIRF集成在一起.
- 同时进行光成像和光谱采集.
- 使用光成像和纳米粒子光谱的性能评估.
主要成果:
- 成功整合了AFM和多波长TIRF.
- 证明了同时进行光成像和光谱采集.
- 通过纳米粒子分析验证性能.
结论:
- 新型的AFM-TIRF系统提供了同时操纵和检测能力.
- 这种相关系统是单分子光研究的一个有前途的工具.
- 该仪器促进了先进的纳米尺度研究.
相关概念视频
Total Internal Reflection Fluorescence Microscopy
5.7K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
5.7K
Super-resolution Fluorescence Microscopy
6.9K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
6.9K
Atomic Force Microscopy
3.4K
Atomic force microscopy (AFM) is a type of scanning probe microscopy that can analyze topographic details of various specimens like ceramics, glass, polymers, and biological samples. AFM offers over 1000 times more resolution than the optical imaging system. Images generated from AFM are three-dimensional surface profiles, offering an advantage over the flat, two-dimensional images from other imaging techniques.
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
3.4K
Confocal Fluorescence Microscopy
13.2K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
13.2K
Atomic Fluorescence Spectroscopy
274
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
274
Fluorescence and Phosphorescence: Instrumentation
576
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
576