在女性中,双臂间血压差异的患病率明显较高;维博格基于人口的查计划 (VISP)
Marie Dahl1,2,3,4, Jesper Winkler Andersen5, Jes Lindholt5,6,7,8,9
1Vascular Research Unit, Department of Surgery, Viborg Regional Hospital, Toldbodgade 12, Viborg, 8800, Denmark. marie.dahl@rm.dk.
BMC public health
|July 12, 2024
概括
双边血压测量对于心血管健康至关重要. 双臂间血压差异 (IAD) 在女性中更常见,并突出了潜在的高血压错误分类.
科学领域:
- 预防心血管疾病预防心血管疾病
- 高血压查 高血压查
- 周围动脉样硬化检测检测
背景情况:
- 双边血压 (BP) 测量对于识别手臂间BP差异 (IAD) 和高血压至关重要.
- 研究了性别分层的IAD患病率及其与外周动脉样硬化和高血压的关联.
- 在使用下与上臂BP读数时确定错误分类率.
研究的目的:
- 为了调查性别分层的手臂间血压差异 (IAD) 的流行情况.
- 检查IAD与查检测到的外周动脉样硬化和高血压之间的关联.
- 根据手臂血压读数量化高血压错误分类.
主要方法:
- 使用了来自Viborg查计划 (VISP) 的数据,涉及4,517名参与者.
- 定义的IAD是缩血压差 ≥10mmHg.
- 使用后勤回归和Venn图来分析IAD关联和与高血压的共存.
主要成果:
- 在女性 (26.8%) 比男性 (21.0%) 中,IAD 的流行率更高,在调整后仍然存在 (OR 1.53).
- IAD与高血压 (血压≥140/90 mmHg) 有显著的关联.
- 大约有15%的人在使用下臂血压读数时被错误地归类为非高血压.
结论:
- 女性性别是IAD患病率的一个独立因素.
- 双边血压测量改善了高血压检测,减少了错误分类.
- 进一步的研究应该评估IAD对心血管事件的预测价值.
相关概念视频
Pre-Procedural Guidelines for Assessing Blood Pressure
542
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
542
Assessment of blood pressure in brachial artery(two-step method)
680
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
680
Assessment of blood pressure in brachial artery(one-step method)
573
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
573
Special considerations while measuring blood pressure
712
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
712
Assessing Blood pressure using a doppler ultrasound
1.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.3K
Assessing Blood pressure in the Leg
2.3K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
2.3K