相关实验视频
Updated: Jun 21, 2025

07:32
Dynamic Electrochemical Measurement of Chloride Ions
Published on: February 5, 2016
11.4K
在钢筋混凝土结构中影响离子扩散的因素
Qiulang Xu1, Bin Liu2, Lin Dai1
1Guangxi Nanbin Highway Construction and Development Co., Ltd., Nanning 530400, China.
Materials (Basel, Switzerland)
|July 13, 2024
概括
了解混凝土中的离子扩散是防止钢条腐蚀的关键. 诸如水结合剂比率,添加剂,裂,温度,湿度和循环等因素显著影响化物运输和混凝土的耐用性.
科学领域:
- 土木工程 土木工程是指土木工程.
- 材料科学 材料科学 材料科学
- 腐蚀科学 腐蚀科学
背景情况:
- 钢筋混凝土结构面临耐用性问题,因为在富含的环境中钢条腐蚀.
- 了解离子运输机制对于提高混凝土结构寿命至关重要.
研究的目的:
- 总结当前关于影响混凝土中离子扩散的因素的研究.
- 确定影响化物透和混凝土退化的主要环境和物质因素.
主要方法:
- 审查关于混凝土中离子传输的最新国内和国际研究.
- 分析了六个关键因素的影响:水结合率,添加剂含量,裂宽度,环境温度,相对湿度和干湿周期.
主要成果:
- 更高的水结合比率和更宽的裂增加了离子扩散.
- 增加添加剂含量减少了离子扩散.
- 高温,湿度和干湿周期加快离子扩散,降低混凝土的透性阻力.
结论:
- 离子扩散受到混凝土混合物设计,结构完整性 (裂) 和环境条件的重大影响.
- 有效的抗腐蚀策略包括腐蚀抑制剂,表面涂料和电化学处理.
- 需要进一步的研究来优化保护措施和预测长期性能.
更多相关视频
相关概念视频
Corrosion of Reinforcement
174
The corrosion of steel reinforcement within concrete is a process influenced by the material's inherent properties and external factors. The high pH level of around 13, provided by calcium hydroxide present in concrete, initially protects the steel reinforcement by promoting the formation of a passive iron oxide layer on its surface.
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
174
Effect of Sea Water on Concrete
210
Concrete exposed to seawater can undergo degradation like the dissolution of ettringite and gypsum, increasing the material's porosity and decreasing its strength. In contrast, the crystallization of salts within the concrete's pores can cause expansion, particularly above the waterline where evaporation occurs. Nonetheless, this expansion only happens when seawater, enabled by the concrete's permeability, manages to infiltrate the structure.
Concrete in areas between tide marks,...
Concrete in areas between tide marks,...
210
Factors Affecting Creep
132
In normal-weight aggregate concrete, the hardened cement paste is the primary contributor to creep, whereas the aggregates, being stiffer than the cement paste, are more resilient to stress-induced deformation. The stiffness of the aggregates is defined by their modulus of elasticity, and the more voluminous they are in the concrete, the less it will creep.
Further, the water/cement ratio is critical, as a lower ratio increases concrete strength, thus reducing creep. The strength of the...
Further, the water/cement ratio is critical, as a lower ratio increases concrete strength, thus reducing creep. The strength of the...
132
Accelerators
72
Accelerators in concrete serve as admixtures to speed up the hardening process, enabling the concrete to achieve early strength faster. Although accelerators do not necessarily impact the time it takes concrete to set, they reduce this time in practice. A common accelerator is calcium chloride, which is particularly useful for hastening early strength development in cold weather or for rapid repair jobs that require quick heat generation after mixing.
The effectiveness of calcium chloride can...
The effectiveness of calcium chloride can...
72
Reinforcements in Concrete
82
Reinforced concrete is a composite material used extensively in construction, combining the compressive strength of concrete with the tensile strength of steel. This synergy is essential as concrete, while excellent at resisting compression, is weak under tension. Steel bars, or rebars, are embedded in the concrete to handle these tensile forces. The choice of steel is strategic; it shares a similar coefficient of thermal expansion with concrete, which ensures uniformity in response to...
82
Testing Water Quality
105
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
105