双模吸收器的频率转移是由明亮和黑暗模式的合引起的
Yun Chen1,2, Jiangbo Hu3, Shan Yin1
1Guangxi Key Laboratory of Optoelectronic Information Processing, School of Optoelectronic Engineering, Guilin University of Electronic Technology, Guilin 541004, China.
Materials (Basel, Switzerland)
|July 13, 2024
概括
明亮和黑暗模式之间的合强度决定了双模吸收器中的吸收频率. 减少合使吸收峰值更接近,而增加合使它们分开.
科学领域:
- 光学和光子学 在光学和光子学.
- 超材料是指一种超材料.
- 电磁主义 电磁主义
背景情况:
- 双模体吸收器在明亮和黑暗模式之间表现出复杂的相互作用.
- 了解模式合对于控制光吸收至关重要.
研究的目的:
- 为了研究合强度如何影响双模吸收器中的吸收频率.
- 为了得出模式合和吸收特征之间的分析关系.
主要方法:
- 合模式理论与干扰理论相结合.
- 分析导出频率,损耗和合强度之间的关系.
- 使用三种不同的地表结构进行数值模拟.
主要成果:
- 吸收频率显然随着合强度的变化而变化.
- 通过明亮和黑暗模式的合,可以实现电磁诱导的透明度.
- 降低合强度导致吸收峰值趋同;增加强度导致分歧.
结论:
- 该研究提供了一个理论框架,用于控制双模系统中的吸收.
- 地表模拟证实了理论发现的一般性.
- 这项工作为设计可调光学吸收器提供了洞察力.
相关概念视频
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
970
Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single...
970
¹H NMR: Interpreting Distorted and Overlapping Signals
1.0K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.0K
¹H NMR Signal Multiplicity: Splitting Patterns
5.1K
When protons A and X are coupled, their nuclear spin energy levels are slightly modified. This is because the energy required to excite proton A to a spin state parallel to proton X is slightly different from the energy required for it to become anti-parallel to spin X. Consequently, there are two possible excitation frequencies for A (A1 and A2), depending on the spin state of X, and vice versa. The mutual nature of coupling implies that the difference between frequencies A1 and A2, indicated...
5.1K
NMR Spectroscopy: Chemical Shift Overview
1.5K
The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
For instance, the proton...
1.5K
Spin–Spin Coupling Constant: Overview
905
In bromoethane, the three methyl protons are coupled to the two methylene protons that are three bonds away. In accordance with the n+1 rule, the signal from the methyl protons is split into three peaks with 1:2:1 relative intensities. The methylene protons appear as a quartet, with the relative intensities of 1:3:3:1.
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
905
¹³C NMR: ¹H–¹³C Decoupling
1.1K
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.1K


