基于YOLOv8和旋转变压器的改进方法来检测起重机轮轨道故障
Yunlong Li1,2, Xiuli Tang1, Wusheng Liu1
1Beijing Materials Handling Research Institute Co. Ltd., Beijing 100007, China.
Sensors (Basel, Switzerland)
|July 13, 2024
概括
本研究介绍了使用Swin变压器检测特殊设备中各种故障的改进的YOLOv8算法. 改进的模型准确地识别小目标和复杂的背景,在实时故障检测中表现优于现有的方法.
科学领域:
- 工程 工程师 工程师 工程师
- 计算机科学 计算机科学
- 人工智能的人工智能
背景情况:
- 由于各种故障特征和复杂的背景,特殊设备的故障检测面临着挑战.
- 现有的智能检测方法与局部故障作斗争,需要全球信息和背景干扰.
研究的目的:
- 提出一种精细的YOLOv8算法,利用Swin变压器来增强特殊设备的故障检测.
- 改善不同尺度和形态特征的断层的检测,特别是在混乱的环境中.
主要方法:
- 使用Swin变压器作为YOLOv8的基础网络,以增强功能提取.
- 实施了多头自我注意力机制,带有滑动窗口,以扩大特征观察的范围.
- 引入了一个非对称的特征金字塔网络,以改进较小目标的空间特征提取.
主要成果:
- 拟议的方法有效地解决了特殊设备智能故障检测方面的挑战.
- 与主流目标检测模型相比,表现出优越的性能.
- 实现了对设备故障的实时检测能力.
结论:
- 精致的YOLOv8算法与Swin变压器显著提升了专用设备的智能故障检测.
- 该方法提供了小目标的准确定位和对背景噪声的强大性能.
- 这种方法为工业环境中的实时,高精度故障诊断提供了有希望的解决方案.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.6K
08:27Author Spotlight: Efficient Image Recognition Using Directional Gradient Histogram Technique and Support Vector Machines
Published on: January 5, 2024
1.0K
相关概念视频
Instrument Transformers
83
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
83
Three-Winding Transformers
221
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
221
Transformers with Off-Nominal Turns Ratios
149
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
149
Energy Losses in Transformers
860
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
860
Types Of Transformers
965
Transformers can provide desired voltages to a circuit by modifying the number of turns in the secondary windings.
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
965
Equivalent Circuits for Practical Transformers
410
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
410