四种不同的口腔内扫描仪的比较分析:一个体外研究
Lucian Toma Ciocan1, Vlad Gabriel Vasilescu1, Sabina-Ana Răuță2
1Discipline of Dental Prosthetics Technology, Faculty of Dentistry, "Carol Davila" University of Medicine and Pharmacy, Dionisie Lupu Street, No. 37, District 2, 020021 Bucharest, Romania.
Diagnostics (Basel, Switzerland)
|July 13, 2024
概括
四个口腔内扫描仪进行了测试,以确定全牙弧印记的准确性. 三元组5显示出最高的精度,符合临床标准,而其他三元组也可靠地对牙患者进行了检查.
科学领域:
- 牙科技术 牙科技术
- 数字牙科数字牙科
- 生物医学工程 生物医学工程
背景情况:
- 内耳扫描仪正在迅速发展,频繁更新硬件和软件.
- 评估这些设备的精度对于临床采用至关重要.
研究的目的:
- 从四个领先的口腔内扫描仪中定量评估全牙门数字印记的精度.
- 将3Shape Trios 5,Dentsply Sirona CEREC Primescan,Planmeca Emerald S和Medit i700的准确性进行比较. 这两种仪器的准确性都非常高.
主要方法:
- 根据ISO 20896-1.创建了一个大虚拟牙科模型 (主模型).
- 用四个口内扫描仪中的每一个扫描15次3D打印模型.
- 扫描器输出与主模型之间的偏差以微米计量.
主要成果:
- 精度各不相同,在扫描中偏差在23至32微米之间.
- 前部区域显示出更高的精度 (112 μm MAD) 比后部区域 (127 μm MAD).
- 3Shape Trios 5表现出最好的精度 (112 微米),其次是Medit i700 (114 微米) 和Planmeca Emerald S (117 微米). Dentsply Sirona Primescan显示了最大的偏差 (127微米).
结论:
- 所有经过测试的口内扫描仪在牙患者的全门扫描中都显示出可靠性,达到或接近临床准确度值 (通常为200微米).
- 3Shape Trios 5超过了基准,而Emerald S和Medit i700也符合标准.
- 普莱姆斯坎接近临床可接受性的上限,这表明尽管在这种体外研究中偏差较高,但其潜在效用仍然很高.
相关概念视频
Assessing Body Temperature - Oral
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Overview of Microscopy Techniques
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
Assessment of the Mouth
A thorough mouth assessment, including inspection and palpation of the lips, gums, tongue, tonsils, uvula, and pharynx, is crucial in detecting potential health issues. Diseases ranging from oral cancer to systemic conditions like diabetes could be identified early through careful oral examination. This article provides a detailed guide on conducting a comprehensive mouth assessment.
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Three-Dimensional Microscopy in Microbiology
Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...


