在数字3D四极离子陷中单频离子停车
Liangxuan Fu1, Gregory S Eakins1, Mark S Carlsen1
1Department of Chemistry, Purdue University, West Lafayette, IN, USA 47907-2084.
概括
数字离子陷 (DIT) 中的单频离子停放可用于电喷式质谱学,可控制电荷降低. 这种技术将离子集中到更少的电荷状态中,方便对大型蛋白质的分析.
科学领域:
- 分析化学 分析化学
- 质谱测量质量谱测量
- 物理化学 物理化学
背景情况:
- 单频离子停车是一种电喷式质谱学 (ESI-MS) 中的减电技术.
- 它利用气相离子/离子反应在电动离子陷中,由振荡电压调节.
- 这种方法控制电荷减少,将离子集中到更少的电荷状态中,这对于分析高质量-电荷 (m/z) 比率的离子至关重要.
研究的目的:
- 为了证明离子停车在作为数字离子陷 (DIT) 操作的3D四极离子陷中的可行性.
- 为DIT应用调整之前描述的离子停车模型.
- 使用这种适应技术来分析大型蛋白质.
主要方法:
- 采用3D四极离子陷作为DIT,并使用数字波形来捕捉RF.
- 使用缓慢的振幅,单频正弦波来选择性地抑制离子/离子反应速率.
- 应用修改的离子停车模型来解释实验数据.
主要成果:
- 成功证明了选择性离子反应抑制在DIT中的离子停车.
- 调整后的模型准确地解释了蛋白质的实验数据.
- 启用了对质量从8600Da到467,000Da的蛋白质的分析.
结论:
- 在使用单频正弦波的DIT中,离子停车是可行的.
- 调整后的模型为理解和优化DIT中的离子停车提供了一个框架.
- 这种技术提高了DIT分析大型生物分子的能力.
相关概念视频
Mass Analyzers: Common Types
586
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
586
Mass Analyzers: Overview
630
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
630
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
697
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
697
Tandem Mass Spectrometry
959
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
959
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
208
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
208
Double Resonance Techniques: Overview
197
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
197