"Alexa,循环血压":用于麻醉监控的语音控制接口方法
Grace Lee1, Christopher W Connor1,2,3,4
1From the Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital-Harvard Medical School, Boston, Massachusetts.
Anesthesia and analgesia
|July 15, 2024
概括
语音识别技术为控制麻醉监视器提供了一个实用的解决方案,提高了麻醉师的可用性. 这种创新方法提高了情境意识,并允许在需要自由手操作时控制设备.
科学领域:
- 医疗器械 医疗器械
- 人与计算机的交互
- 麻醉学 麻醉学
背景情况:
- 传统的麻醉监视器依赖于物理控制,如拨号和触摸屏,限制了麻醉师的可访问性.
- 语音识别技术为克服物理限制和减少手术室污染提供了机会.
- 这项研究探讨了麻醉器件语音控制的可行性和实用性.
研究的目的:
- 开发和评估一种用于麻醉患者监视器的新型语音驱动控制器.
- 评估语音识别技术在麻醉实践中的可行性和有用性.
- 为了确定麻醉师对语音控制系统的接受.
主要方法:
- 一个语音控制器的原型是使用Raspberry Pi,谷歌云语音到文本以及改造的GE太阳能8000M显示器进行工程设计的.
- 50名麻醉提供者在非临床环境中测试了该原型.
- 用户反通过调查收集,评估易用性,有用性和有效性.
主要成果:
- 语音驱动控制器得到了一致的好评,在易用性,实用性和有效性方面获得了很高的评分.
- 在用户接受度和训练水平,口音或声调等因素之间没有发现显著的相关性.
- 该技术展示了将其集成到麻醉工作流程中的巨大潜力.
结论:
- 语音识别是控制麻醉监视器和设备的一个有前途的技术.
- 它可以提高可用性和情境意识,特别是当麻醉科医生身体受到限制或任务繁重时.
- 该系统显示,用户接受度与人口或声音特征之间没有不利的关系.
更多相关视频
相关概念视频
Equipments Used To Measure Blood Pressure
950
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
950
Pulse rhythm
782
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
782
Special considerations while measuring blood pressure
712
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
712
Assessing Blood pressure using a doppler ultrasound
1.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.3K
Assessment of blood pressure in brachial artery(two-step method)
680
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
680
Pre-Procedural Guidelines for Assessing Blood Pressure
542
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
542