可见流体运动对操纵作为手术内确定的膝关节关节整形部件松动的新门:Delphi研究
George S Buijs1,2, Arthur J Kievit1,2, Alex B Walinga1,2
1Department of Orthopedic Surgery and Sport Medicine, Amsterdam UMC, Location AMC, Amsterdam, The Netherlands.
概括
在膝关节修复外科医生之间达成共识,定义了手术内确定的部件松. 在特定的运动或温和的力量中,在接口上可见的流体运动现在是膝关节关节整形部件松动的标准定义.
科学领域:
- 整形外科手术 整形外科手术
- 生物医学工程 生物医学工程
- 医疗器械研究 医疗器械研究
背景情况:
- 膝关节关节整形部件松动的术内评估缺乏标准化的定义.
- 这种模糊性使得诊断研究结果的解释和比较变得复杂.
研究的目的:
- 在专门的膝关节修复外科医生之间就术内确定的松的定义建立共识.
- 为在手术期间评估膝关节关节整形组件稳定性创建统一的标准.
主要方法:
- 在一个由膝关节修复外科医生组成的国际小组中,采用了德尔菲共识方法.
- 一个三轮的过程涉及开放式问题,利克特级别评分,以及在定义上建立共识.
- 超过70%的参与者将共识定义为同意.
主要成果:
- 34名外科医生参与,产生了60个初始标准,34人达到了共识.
- 提出了四个定义,88%的人同意一个关键标准.
- 一个组件被认为是松散的,如果在特定运动或温和的直接力时在接口上观察到可见的流体运动.
结论:
- 成功地建立了一种对手术内确定的膝关节关节整形部件松的共识定义.
- 基于可见流体运动的新定义为未来的研究提供了标准化的参考.
- 这种标准化将提高组件松动的诊断研究的可解释性和可互换性.
相关概念视频
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
189
Effective lubrication between a rotating shaft and its bearing housing is essential in rotating machinery to minimize friction, wear, and energy loss. With carefully controlled thickness and viscosity, the lubricant layer prevents metal-to-metal contact, ensuring smooth operation.
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular...
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular...
189
Fluid Movement Between Compartments
2.3K
The force applied by fluids against a surface, known as hydrostatic pressure, initiates the transfer of fluid among different compartments. Within our blood vessels, the blood's hydrostatic pressure is a result of the heart's pumping action. At the arteriolar end of capillaries, hydrostatic pressure (capillary blood pressure) exceeds the opposing colloid osmotic pressure created primarily by plasma proteins like albumin. This discrepancy in pressure propels plasma and nutrients from the...
2.3K
Knee Joint
2.6K
The knee joint is the most complicated joint in the body. It consists of three articulations– two tibiofemoral and one patellofemoral. As is characteristic of synovial joints, the knee joint has a thin articular capsule that partially surrounds this joint cavity. Additionally, several ligaments, muscles, and cartilaginous structures support the movement of the knee.
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
2.6K
The Fluid Mosaic Model
167.6K
The fluid mosaic model was first proposed as a visual representation of research observations. The model comprises the composition and dynamics of membranes and serves as a foundation for future membrane-related studies. The model depicts the structure of the plasma membrane with a variety of components, which include phospholipids, proteins, and carbohydrates. These integral molecules are loosely bound, defining the cell’s border and providing fluidity for optimal function.
167.6K