在KAMINI反应堆南梁门附近使用嵌套中子子谱仪测量中子谱
D Venkata Subramanian1, Adish Haridas1, D Sunil Kumar1
1Reactor Shielding and Data Division, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102, India.
Radiation protection dosimetry
|July 17, 2024
概括
研究人员描述了通过研究反应堆流动的中子.
科学领域:
- 核工程 核工程是指核工程.
- 辐射屏蔽 辐射屏蔽
背景情况:
- 卡尔帕卡姆MINI反应堆 (KAMINI) 是一个以233U为燃料的研究反应堆.
- 在南光门附近的中子和马剂量率分别为275-300μSv/h和175-200μSv/h,在10kW运行下测量.
- 由于中子和马射线的流动,即使有屏蔽,也存在显著的辐射剂量.
研究的目的:
- 首次描述了门上的流动中子谱.
- 测量中子流量,平均能量和环境剂量等效率.
- 为了将测量结果与来自南梁坑的早期数据进行比较.
主要方法:
- 使用嵌套中子光谱仪进行光谱表征.
- 在卡米尼反应堆的南梁门进行测量.
- 屏蔽和未屏蔽的中子光谱和剂量率的比较.
主要成果:
- 帕拉芬盾的存在使中子平均能量从370 keV降低到178 keV.
- 在10kW时,中子流被减弱了25000倍.
- 在屏蔽后,测量位置的中子光谱变得更加热化.
结论:
- 该研究成功地在KAMINI反应堆门上特征了流中子子谱和剂量率.
- 石屏蔽有效地减少了中子能量和流量.
- 创建中子参考数据用于顶门位置.
更多相关视频
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
2.3K
08:48High-Resolution Neutron Spectroscopy to Study Picosecond-Nanosecond Dynamics of Proteins and Hydration Water
Published on: April 28, 2022
1.7K
相关概念视频
Atomic Emission Spectroscopy: Instrumentation
359
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
359
Atomic Emission Spectroscopy: Lab
154
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
154
Nuclear Binding Energy
12.4K
The difference between the calculated and experimentally measured masses is known as the mass defect of the atom. In the case of helium-4, the mass defect indicates a “loss” in mass of 4.0331 amu – 4.0026 amu = 0.0305 amu. The loss in mass accompanying the formation of an atom from protons, neutrons, and electrons is due to the conversion of that mass into energy that is evolved as the atom forms. The nuclear binding energy is the energy produced when the atoms’ nucleons...
12.4K
Nuclear Fission
9.6K
Many heavier elements with smaller binding energies per nucleon can decompose into more stable elements that have intermediate mass numbers and larger binding energies per nucleon—that is, mass numbers and binding energies per nucleon that are closer to the “peak” of the binding energy graph near 56. Sometimes neutrons are also produced. This decomposition of a large nucleus into smaller pieces is called fission. The breaking is rather random with the formation of a large...
9.6K
Atomic Absorption Spectroscopy: Radiation and Light Sources
381
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
381
Nuclear Stability
18.7K
Protons and neutrons, collectively called nucleons, are packed together tightly in a nucleus. With a radius of about 10−15 meters, a nucleus is quite small compared to the radius of the entire atom, which is about 10−10 meters. Nuclei are extremely dense compared to bulk matter, averaging 1.8 × 1014 grams per cubic centimeter. If the earth’s density were equal to the average nuclear density, the earth’s radius would be only about 200 meters.
To hold positively charged protons together...
To hold positively charged protons together...
18.7K