旅行后的平衡恢复受倒障碍物的类型的影响
Xingda Qu1, Baozhan Yang1, Weiliang Wang1
1Institute of Human Factors and Ergonomics, Shenzhen University, Shenzhen, China.
Ergonomics
|July 17, 2024
概括
不同的倒障碍物会影响跌倒的风险. 板状障碍物比杆状障碍物增加了跌倒风险,原因是旅行后改变了平衡恢复策略.
科学领域:
- 生物力学 生物力学
- 职业安全 在职业安全.
- 人类运动科学科学 人类运动科学
背景情况:
- 职业摔倒通常是旅行造成的.
- 旅行期间的机械力根据遇到的障碍物而异.
研究的目的:
- 为了研究不同类型的倒障碍物如何影响倒后平衡恢复.
- 为了比较杆状与板状障碍物对姿势稳定的影响.
主要方法:
- 64名健康的成年人参加了一项受控的行走实验.
- 使用类似杆状或类似板状的障碍物诱导旅行.
- 衡量平衡恢复参数,并将障碍条件进行比较.
主要成果:
- 与杆状障碍物相比,板状障碍物导致更长的退步时间.
- 在倒板状障碍物时,恢复步骤的持续时间较短.
- 恢复期间的最低部高度在板状障碍物下降,表明平衡控制较差.
结论:
- 倒障碍物的类型显著影响到平衡恢复机制.
- 板状障碍物可能比杆状障碍物构成更高的跌倒风险.
- 未来的研究应该考虑在旅行和跌倒的研究中的障碍特征.
相关概念视频
Line Protection with Impedance Relays
76
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
76
Differential Relays
125
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
125
Reclosers and Fuses
100
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
100
Directional Relays
103
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
103
Friction: Problem Solving
218
Friction is an essential force that influences the motion of objects in daily life. Depending on the situation, it can be either beneficial or problematic. Consider a bus with a mass of three megagrams and its center of mass at a specific point, moving along a banked road at a constant speed. The coefficient of static friction between the tires and the road is 0.5. Find the maximum angle of the banked road at which the bus would not slip or tip.
Initially, a visual representation of the...
Initially, a visual representation of the...
218
Three-Phase Short Circuit—Unloaded Synchronous Machine
134
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
134


