新兴国家的电力系统转型:一个SWOT/PESTLE分析方法,以提高弹性和可靠性
Kokou Amega1, Yacouba Moumouni2, Yendoubé Laré3
1West African Science Service Centre on Climate Change and Adapted Land Use (Wascal), University Abdou Moumouni of Niamey, Po. Box:10662 FAST/UAM, Niamey, Niger.
Heliyon
|July 18, 2024
概括
发展中国家由于高需求和障碍,面临着电力系统挑战. 本研究确定了新兴经济体的关键障碍,并提出了适应性电力基础设施和改善生活条件的解决方案.
科学领域:
- 能源政策 能源政策
- 电气工程 电气工程
- 发展经济学 发展经济学
背景情况:
- 发展中国家的电力系统受到不断增长的需求和运营障碍的压力.
- 解决电力行业的挑战对于提高新兴经济体的生活水平至关重要.
研究的目的:
- 确定阻碍新兴经济体电力公司的主要因素.
- 提出可行的策略来克服这些障碍.
- 分析托哥的电力系统作为一个代表性的案例研究.
主要方法:
- 综合模型,结合文献综述和调查.
- 与能源部门专家的采访.
- 用SWOT/PESTLE分析进行综合评估.
主要成果:
- 电气化贫困率为39.47%,到2030年需要额外的220.95兆瓦,以实现通用电力供应.
- 系统性能受到政策/监管限制,传输和分配的技术问题以及投资不足的限制.
- 缺乏激励措施和税收减免进一步加剧了这些挑战.
结论:
- 提出了一种弹性电力系统模型,用于改造发展中国家过时的基础设施.
- 主要重点领域包括能源组合规划,输电和配电创新以及区域合作.
- 实施这些战略可以带来可靠和安全的电力供应.
相关概念视频
Multimachine Stability
150
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
150
Turbine-Governor Control
197
Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
197
Transformers in Distribution System
99
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
99
Distribution Reliability and Automation
107
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
107
The Power Flow Problem and Solution
189
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
189
Power System Distribution
231
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
231