在使用Watchman装置关闭左心房附属体后,与设备相关的血栓的发生率和预测因素
Jakub Maksym1, Piotr Scisło1, Agnieszka Kapłon-Cieślicka1
1First Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland.
概括
在左心房附带关闭 (LAAC) 后的设备相关血栓 (DRT) 是罕见的,但与患者因素有关. 较低的射出分数,较低的LAA排空速度和更深的植入预测心房患者的DRT.
科学领域:
- 心脏病学 心脏病学
- 医疗器械 医疗器械
- 血栓形成的原因之一是血栓形成.
背景情况:
- 使用Watchman设备关闭左心房尾 (LAAC) 是一种预防心房动 (AF) 患者血栓栓塞的策略.
- 一个潜在的并发症是植入装置的心房表面上发生与装置相关的血栓 (DRT).
研究的目的:
- 为了确定与设备相关的血栓 (DRT) 的发生率,这些患者使用Watchman设备接受了LAAC.
- 确定与DRT形成相关的患者和程序预测因素.
主要方法:
- 78名AF患者的回顾性分析,这些患者使用第一代Watchman 2.5设备进行了LAAC.
- 患者在手术后接受了抗血小板治疗.
- 经食道心声学 (TEE) 用于临床随访,以评估DRT.
主要成果:
- 与设备相关的血栓 (DRT) 在6.4%的患者中被观察到.
- 预测DRT的预测因素包括较低的射出分数,较低的左心房附属体 (LAA) 排空速度,更大的植入深度,更大的LAA尺寸和更年轻的患者年龄.
- 接受DRT的患者具有显著较低的射出分数 (p=0.005),较低的LAA排空速度 (p=0.009),以及更大的植入深度 (p<0.001).
结论:
- 对LAAC的Watchman设备植入后的设备相关血栓 (DRT) 是一个不常见的并发症.
- 特定的患者特征和程序因素似乎与DRT发展有关.
- 需要在更大的队列中进行进一步的调查,以确认这些发现并完善风险分层.
相关概念视频
Equipments Used To Measure Blood Pressure
3.4K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.4K
Errors occurring during blood pressure monitoring
1.6K
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
1.6K
Holter Monitor: 24-Hour Monitoring
5.7K
Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
5.7K
Cardiac Catheterization II: Right Heart Catheterization
2.2K
Right Heart Catheterization: An OverviewRight heart catheterization is an invasive diagnostic procedure that measures right-sided cardiac and pulmonary artery pressures, calculates cardiac output, and identifies intracardiac shunts. It provides detailed hemodynamic data essential for diagnosing and managing various cardiovascular conditions, such as pulmonary hypertension.Access SitesCommon access sites for right heart catheterization include the internal jugular vein in the neck region, the...
2.2K
Cardiac Catheterization III: Left Heart Catheterization
1.3K
Left heart catheterization is an invasive diagnostic procedure used to evaluate the function and structure of the left side of the heart. It is generally performed to diagnose and treat cardiovascular conditions such as valve abnormalities, coronary artery disease, and congenital heart defects.Diagnostic and therapeutic purposesLeft heart catheterization serves various diagnostic and therapeutic purposes, including:Assessing coronary artery bypass grafts.Evaluating coronary artery disease in...
1.3K
Aortic Regurgitation III: Medical Management
598
Aortic regurgitation (AR) is when the aortic valve does not close or seal properly, leading to backward blood circulation from the aorta into the left ventricle during diastole. Common causes of AR include rheumatic heart disease, congenital valve defects, and aortic root dilation. Managing AR requires a multifaceted approach to alleviate symptoms, preserve left ventricular function, and address the underlying cause of the regurgitation. Patients with symptomatic AR or significant left...
598